  1. HVAC
    Hey all! Been reading the forum for a few days now in hops of finding someone with similar issues, but alas... no. Problem with the Payne HVAC unit. When on HEAT mode and the wall thermostat starts the heat cycle, 7-8 min later, the wall thermo looses 24V and goes dark. At the same time, the...
  2. Appliances
    Greetings... I have a Payne Model 395BAW036095 that is operating normally when the house is up to temperature and the heater is only working to maintain that temperature. However, when the house is cold and the furnace is called upon to bring the temperature up from say 56 degrees to 68 or 70...
  3. HVAC
    I have a Payne PG8UAA036065 gas furnace. For the past three years I have had issues with my furnace getting a code 21, which is: GAS HEATING LOCKOUT - Control will NOT auto reset. Check for: - Mis-wired gas valve or Defective control(valve Relay) The issue is intermittent, It may run for one...
  4. HVAC
    I have a Payne 376C Furnace the I just replaced the controller board with a new ICM281. When all is connected up properly the self test works properly with all actions being taken in their proper order. First the Inducer turns on the the HSI starts glowing then the blower turns on at low speed...
  5. HVAC
    This is my first time buying a furnace, and it is for my rental property in southeastern Michigan. I will never end up living in the house, but I plan on owning it for a long time. I try to find tenants that will be good to the house but that is easier said than done. The 1200 sq ft house...
  6. HVAC
    My Payne furnace is toast. The board lights up with code 31. I noticed that there are two fan motors, One small one, and One big one. The Big fan starts first works for about 2 minutes then shuts off. Then the small fan starts spinning and nothing happens after that. I was told that some...
  7. HVAC
    I have a Payne PG8JAA/MAA vented with a power vent. When there is a call for heat before the power vent has shut down fully, the furnace goes into lockout (code 23). At that point, the power vent stays on indefinitely and the house gets very cold. It can be reset by turning the thermostat off...
  8. HVAC
    I have a 1 year old Payne gas heat and air unit, model #py3pna024060ab. First time this year I tried to turn heat on and is not working. AC works fine, fuses tested good, and I believe the thermostat is o.k.; when I turn on heat the unit makes a fan noise and I hear a clicking about every 30...