  1. HVAC
    Hi all, my draft inducer is hesitating periodically when it starts. I suspect it's a loose black wire I noticed - coming out of the bottom white connector (circled in bottom of photo). Do I need to use the white connector? Would I be able to cut the black wires and connect them via spade...
  2. HVAC
    So I've been frustrated trying to figure out a furnace issue. The inducer blower turns on but the igniter won't glow. After a while of troubleshooting, I figured out the igniter is fine but there doesn't seem to be enough airflow from the blower to close the pressure switch. I thought maybe...
  3. HVAC
    Good evening, I have a York YP9C furnace. When I went to switch on the heat, nothing happened. Looking at the control board (FCB), i have 3 quick red blinking lights to indicate a pressure switch issue, however this is due to the inducer motor not turning on. I have diagnosed to board myself...
  4. HVAC
    Hey Gang, First time poster here. Went to fire up the heat for the first time this season yesterday, and after 30 minutes I noticed it had been blowing the whole time, but there was no heat. This is a model number GUI075A012AIN. Taking a closer look, I saw that I had three blinking lights...
  5. HVAC
    Hi everyone. I have a strange question that I was hoping for some opinions on. Three days ago, I had someone out to do a 30-point inspection on my furnace which was functioning properly. I was expecting a sales pitch and I have some experience with HVAC and a lot of experience with...
  6. HVAC
    The draft inducer on my furnace is not coming on. The switch clicks like it is telling the inducer motor to kick on, then the furnace ingnitor comes on and the furnace is heating. But the heated air is not going anywhere since the inducer isn’t coming on. Is it safe to say I need to replace the...
  7. HVAC
    New member here. I have an old Ruud Silhouette 2 75,000 BTU 80% upflow gas furnace from 1995, and ever since yesterday the blower motor and inducer stay on after every heat cycle unless I turn the power off to the furnace and wait about 15 mins to turn it back on. If I turn the power back on any...
  8. HVAC
    We bought a house this October and the heating has some strange symptoms that i can't seem to fix. It's a keeprite gas, air heating. I had the repair man over already and of course everything worked like a charm so its quite intermittent. - when it starts up it tries usually 2 times. the...
  9. HVAC
    Hi there, thanks for reading this thread. We have a 15 years old Day&Night gas furnace that has been working fine until now. For some reasons over the past two weeks, the unit (furnace) became so hot that it would just shut down by itself, which we will have to then go to the basement and...
  10. HVAC
    I'm troubleshooting an 80% furnace with an IFC board and its inducer blower motor stays on constantly even though the thermostat is set on Off and the fan on AUTO. Any suggestions anyone
  11. HVAC
    I just replaced the inducer motor on my payne furnace and now the furnace does not shut down after reaching the desired temperature. We did not have this problem before the inducer motor went out. can anyone advise?
  12. HVAC
    I have a Carrier 58CTA135 furnace that is 5 years old. The inducer motor recently failed. A tech installed a new motor today, but after working with it for nearly 2 hours, he told me he could not get the motor to spin without the inducer wheel hitting the housing. He recommended I replace...
  13. HVAC
    Hey all. I have a Carrier 58 PAV Furnace, and for the past several days it's been making an increasingly disturbing noise, a high pitched humming/whistling noise, that is coming from the induction motor assembly. When the motor assembly turns off, it sounds like a jet engine powering down...
  14. HVAC
    Hi, I have a Carrier 58PAV07-08, series 180, s/n 2801A50213 It started intermittently making noises. The noises generally start before the burner kicks in, and last until the end of the shutdown sequence. From my reading here, that would seem to indicate the induction motor. The inducer...
  15. HVAC
    Hi, I recently had a repairman tell me my control board was bad, the hot surface igniter was reading high, and the inducer motor bearings were going out...and I need a new furnace due to cost to fix. I decided to repair it myself and now I'm a bit stuck. I replaced the the control board and...