1-12 of 12 Results
  1. HVAC
    I have a Rheem condenser unit. About once every other day, the condenser fan will stop running even though the the rest of the AC system is still running (at which point the AC blows warm air). I can make everything run correctly again if I turn the AC off with the thermostat and then turn the...
  2. HVAC
    My Carrier AC stopped working several days ago. I could hear a light humming from the outside unite, but would not kick on. By the way, the last few years I have had to use a screwdriver to spin the blades to "kick start the season". That no longer works. So I replaced the capacitor and fan...
  3. HVAC
    My fan motor for a Rheem Ruud condenser seized up. I called around and found a replacement. I wired it up according to the wiring diagram and even added a new capacitor like it said. It started fine and cold air started to come out of the vents. After about 20 minutes of it running it shut off...
  4. HVAC
    The fan motor to our AC condenser has stopped working and we are looking for a new one. The existing one is as follows: MFG: GE MOTORS EQUIP MFRS #: HC39GE232A MODEL: 5KCP39FG V: 208 - 230 AMPS: 1.40 CAP: 5.00/370 HP: 1/4 RPM: 1100 We are trying to cross reference the above part, but...
  5. HVAC
    So i have to replace the condenser fan motor, it wont spin freely and it looks like the bearings are worn out. The old motor says it is a 1/4hp with 2.2 FLA(full load amps), 208/230V, PH1. It does not say what the rpm's are and neither does the fan blade. So i found on Grainger two motors that...
  6. HVAC
    Woke up this morning and thermostat was set to 75 but temp was 85. The air handler was working and vents were blowing air but not cold. Went outside and condenser isnt working, the fan isnt blowing. Reset the breaker, didnt help, checked condenser with voltage tester and it is getting power. I...
  7. HVAC
    Please help!:confused1: I have a less than two years old Trane AC unit that has stopped spinning its fan blades. When I turn on the unit the compressor kicks on and sounds like it normally does but there is just no spinning of the fan. I have tried the stick test to no avail. The blades...
  8. HVAC
    Last week we replaced the compressor fan motor on our 5 year old Amana system. We discovered that one night the fan stopped running and would not kick back on, no matter how much time we killed the power to the unit. I have a friend of a friend who is a licensed HVAC technician who came out...
  9. HVAC
    I have a Bryant model 597CNO36-D compressor outside that is regularly tripping the house panel breaker and then after the breaker is reset, it will run, but periodically make a loud screeching noise. I believe it is the fan making the noise, but I am not certain. I have shot the following 37...
  10. HVAC
    OK. You guys helped me out a few weeks ago with an A/C suction line question and it really helped. I did have a tech come out and check my first unit and he said I did a good job insulating the suction line and the unit checked out OK. Tonight my second unit stopped working correctly. I...
  11. HVAC
    I live in the Ocoee, Fl. area(nearby Orlando) and I have a Carrier/Puron Refrigerant Air Condition Unit (Model# 38EYG048301) and it stopped working several days ago. The Air Handler (Model# FK4DNB006000AAAA, Mfg. Carrier) works fine. In about 10-15 minute intervals I hear a sound coming from the...
  12. HVAC
    My heat pump has a 5kcp39fg "r560s" motor in it a 1/4 hp, volt 208/230, 1100 rpm motor to be exact. I found ver inexpensive a 5kcp39fg "m599s" motor for sale which has the same specs. Should I buy it or should I just buy oem and spend an extra $150? Will it work, will I have to find a capasitor...
1-12 of 12 Results