  1. HVAC
    Nordyne split system blowing main board fuse when A/C contactor wire energized E183 I have a split system 2.5 ton HVAC unit. I have a NEST thermostat I started getting error E 183 two weeks ago and the A/C blower shuts off I tried sending 24 volts...
  2. Electrical
    I need to control a 240volt 15amp circuit and a 120V 20 amp circuit with one switch. I plan to get a 20amp (definite purpose?? ) 2 pole 120volt coil normallyl open circuit. The ABB product has 450ohm coil resistance, so I calculated about .3amp for the coil. I will run the 120volt circuit...
  3. Electrical
    This hottub has a 240V 4 wire 15amp circuit, and a 120volt 20amp circuit. The wiring had been installed all directly on the floor in a spot where water was dripping on it. It also had improper circuit breakers that would have only knocked out one of the phases of the 240V. We put the wires in...
  4. HVAC
    Hello All, I have run into a little trouble with my A/C and furnace today. I noticed my A/C had not kicked on in a while, upon inspection I found the 5 amp fuse on my control board was burnt. I replaced the fuse and turned my furnace back on, when I turned my thermostat to cool the fuse burnt...
  5. HVAC
    Can anyone help? I replaced my contactor in my outside unit and still when i switch to cooling the fan and compressor does not turn on until i manually push the bridge on the contactor. Any ideas?
  6. HVAC
    Hi all hope most of you are managing to stay cool!!!!!!! Looking at the image, does it look like it's time to replace my AC condenser's contactor?
  7. HVAC
    Our thermostat comes on, the air handler blows, but the outside unit does not come on. We tested the capacitor, its fine. We replaced the single. Pole contactors with a double pole, everything seems to test fine but the fan and compressor don't come on. When we manually override the contactor it...
  8. HVAC
    Hi, Can anyone help me find the correct contactor for my old GE central AC unit? I've tried searching using the model number. But I don't get any results. The equipment tag is pretty difficult to read. Here is what I've been able to make out. (I use the exact nomenclature used on the tag and "?"...
  9. Electrical
    Hello all, I have the following weird problem I am trying to figure out. I have a mechanical timer that control a contactor that controls two circuits of external light (CFLs with ballast). Each circuit is connected to one of the 4 phases of the contactor. From the get got one circuit would...
  10. Electrical
    I have a 240v50amp circuit (2h/g) and I want to control the line current to the outlet via a timer. Simple enough to do with a contactor and a 120v timer. The complicated part is that I actually want to control the line current to two different outlets and if I could design my own contactor...
  11. HVAC
    I have a heat pump that I am having a significant issue with. When it is very hot outside (~85 Deg F or above), the unit runs fine and cools well. However, when it cools off slightly, the A/C will not run even though the stat is still calling for cooling. What happens when it is cooler is...
  12. HVAC
    I need help converting from the Ge 97f9898 to the AmRad Turbo 200. There are 6 wires coming off the ge and the AmRad schematic says and shows there should be 4 wires coming off of it (the Turbo 200) not 6. Not sure what to do here. Any help would be appreciated.
  13. HVAC
    Lennox split unit. 240v getting to and from contactor inside the condenser but not getting the 24v on the side posts. Condenser works when the reset button is depressed. At the circuit board: I have power getting to board via the black wire through the cover switch and a small amount of...
  14. Building & Construction
    Hi, new to the forum and loving the information I've been able to gather so far! I was wondering about the estimated costs of refinishing my basement. It was a finished basement when I purchased the house a couple of years ago, unfortunatly I had to have all the 'finished' parts removed due to...
  15. HVAC
    Greetings! I have a split A/C unit that has me perplexed at the moment. When I turn the thermostat down the 24V contactor-relay (mounted on the outside unit) closes and the compressor and condensor both turn on. After about five minutes of run time, the relay starts to randomly open and...
  16. Electrical
    TeleMecanique LC1D0910 has the following contacts: A1, A2 (very top) 1/L1,3/L2,5/L3,13/NO (top) 2/T1,4/T2,6/T3,14/NO (bottom) A2 (very bottom) Matelec Day/Night switch 15Amp model Power source: 230V/50Hz, single phase Project: to turn on security lights (R80 projector) x 8 around the house...