compressor

  1. Tools
    I have a Craftsman 150 PSI Compressor (Model: 919.167310). I just purchased a new Air Regulator to replace the original one that I thought had gone bad since it would drain the main tank pressure to whatever I set the Regulator pressure to. However, when I replaced the old reg with the new reg...
  2. Tools
    I have a Craftsman 150 PSI Compressor (Model: 919.167310). I just purchased a new Air Regulator to replace the original one that I thought had gone bad since it would drain the main tank pressure to whatever I set the Regulator pressure to. However, when I replaced the old reg with the new reg...
  3. HVAC
    My neighbor complained that the A/C is too loud and they are unable to sleep in the night. Our compressor is about 12 ft from the fence and their bedroom window is about 10-15 ft from the fence. The unit is Lennox that we bought last year. I bought a decibel meter and it measures around 60-62...
  4. HVAC
    Hello everyone, Two days ago, my attic unit was making crashing noises to the point where air flow completely stopped. After investigating, some of the blower wheel blades were broken and broke the wheel in general. After replacing the blower wheel with the exact same specs, the attic unit is...
  5. HVAC
    So I live in a college/University community and every year, regardless of viral disease and mayhem, the students throw away tons of furniture, appliances, and the infamous mii fridge. I've scooped a few over the years selling them on craigslist and the like. About 6 months ago I was coming home...
  6. HVAC
    A few days back, I found out that the fan of the HVAC system is running (fan inside is running and heating works fine) but the outside condenser unit is not running. The circuit breaker was tripped and whenever I switch on the circuit breaker, it trips again in 3-5 seconds. I changed the circuit...
  7. HVAC
    My AC has always worked fine. A couple months ago I replaced a battery powered thermostat with a Honeywell Wifi smart thermostat. The new thermostat needed a "C" wire for power and there was an unused dark blue wire behind the old thermostat so i connected it to the "C" port at the furnace...
  8. Appliances
    Not sure this is the right place. Our fridge started to cool less over the last few days. There is a clicking sound but neither the compressor or fan seems to be running. Tested both, as well as the starter relay with a multimeter, all compenents are fine and give appropriate readings.The coils...
  9. HVAC
    The other day I noticed that hot air was coming out of my vents when I had the A/C running. I went and looked at the condenser and the compressor was running but the fan was not and the fan motor was very hot. After doing some studying, I replace the cap and turned the A/C back on but the fan...
  10. HVAC
    I just replaced my condenser fan motor because the bearings were shot in my old one. My unit is a Keeprite KSSD 19-36, probably around 25 years old. The old motor had 4 wires, red, black, brown and white. The new motor's wires are yellow, black, brown, and brown/white. After I installed the...
  11. Tools
    I just bought a small (3 gallon, 100 max PSI) Harbor Freight air compressor, and I'm trying to figure out what else I need to operate my 18-gauge brad nailer with it. The manual says to attach a regulator, which I don't understand because the compressor itself has a regulator that you can set to...
  12. HVAC
    hello thankyou for helping me , my ac blower is running fine but, the compressor and condensing fan start and run for ten seconds then stops. this happens every ten minutes,after 1/2 hour the ac shuts down and there is a timer icon blinking at the display. when compressor and condensing fan stop...
  13. HVAC
    Hello - I need to replace my 20 year old HVAC system and have about six different contractor quotes - ranging in price from about $5K to $10K. Many of the contractor/mfger websites I visited recommend the 2-stage compressors, but the cost difference between single stage (16 SEER) system...
  14. HVAC
    Is there any data out there that correlates AC compressor starting or running amps (vs. max rated values) with overall condition of the AC unit, compressor condition in particular. For example, I'm guessing that as a unit ages it's LRA & RLA with gradually increase...and begin to approach...
  15. HVAC
    Couple nights ago I noticed it was getting warm and muggy in the house. The a/c fan was running in the house, but the air coming out of the register wasn't cool. Went out to the yard and saw that the condenser fan wasn't running. Took the cover off and saw that the capacitor top was domed...
  16. Tools
    I need help removing water from an air compressor line so I can spray paint without issues. I am a total newbie. I have sprayed polyurethane before with really great results (it was about 13 years ago when I built a baby crib for my daughter and the sprayed on polyurethane top coat turned out...
  17. HVAC
    Dear All .. Let's say my 3/4 ton currently run on arround 800 watt @ 220-240 V I plan to put a motor speed control (kind of lamp dimmer) at it's compressor's power input port. This device will alter the voltage . My question is, with the same refrigerant volume and preasure how much minimum...
  18. HVAC
    Fan on 40AQ024300BB unit will not stop running, with compressor also running all the time in cooling mode, even if temperature is set above ambient (Heat Pump) When I turn off fan at thermostat or remove call for fan in inside unit on the contractor relay, fan kept running. Replaced contactor...
  19. Appliances
    How to remove this Haier HF50CW20W chest freezer relay? I'm hoping it's the source of the problem. The freezer turns on for a minute, clicks then turns off. Also, Haier doesn't list a relay for this freezer among it's parts list. My Haier pix Is there a standard relay that is a...
  20. HVAC
    Hello all, My AC stopped blowing cold air yesterday - had a guy come who changed what he claimed to be a blown capacitor that caused the compressor to overheat and trip the thermal reset (I hope I'm not oversimplifying too much here). He hosed the compressor down to cool it off, but said it...