DIY Chatroom Home Improvement Forum - View Profile: Wiredindallas
Advertisement


Go Back   DIY Chatroom Home Improvement Forum > Members List

CLICK HERE AND JOIN OUR COMMUNITY TODAY...IT'S FREE!

Wiredindallas Wiredindallas is offline

Member

Statistics

Total Posts
Blog
Total Thanks
General Information
  • Last Activity: Today 05:29 AM
  • Join Date: 11-09-2018
  • Referrals: 0

Mentions

09-02-2019
01:31 PM - Nefarious mentioned Wiredindallas in post Re: Grounding switch wires
Wiredindallas: I really don't hav...
04-07-2019
01:32 AM - gpraceman mentioned Wiredindallas in post Re: Neutrals/Grounds in Main Panel
@Wiredindallas - Room is a bit tig...
01-30-2019
12:55 AM - Mystriss mentioned Wiredindallas in post Re: Best way to light very long driveways
Wiredindallas Oh no, we had typic...
01-12-2019
03:12 AM - Mystriss mentioned Wiredindallas in post Re: Additional circuits?
@Wiredindallas Yeah, the well wen...
01-11-2019
10:22 AM - Mystriss mentioned Wiredindallas in post Re: Additional circuits?
@Wiredindallas oh I'll be running ...

Quotes

10-10-2019
12:49 PM - rjniles quoted Wiredindallas in post Re: AFCi - outlets vs breakers
By code, the wiring to the 1st out...
10-08-2019
02:42 PM - graymoment quoted Wiredindallas in post Re: Spray foam insulation and vaulted ceiling with recessed lighting. Best practices?
Wherever a light is to be placed b...
10-03-2019
06:15 PM - KK9639 quoted Wiredindallas in post Re: Removed old fuse box and installed a new breaker panel. I have a question.
I am shocked such an old service s...
09-08-2019
09:19 PM - jdj7 quoted Wiredindallas in post Re: Outlet too close to tub
No one seems to realize that the p...
05:40 AM - Gregsoldtruck79 quoted Wiredindallas in post Re: Outlet too close to tub
Because of various reasons, we dec...
09-06-2019
02:04 PM - Photobug quoted Wiredindallas in post Re: SER or THHN in conduit for subpanel.
SER is good as long as it is prote...
09-05-2019
05:10 PM - MTN REMODEL LLC quoted Wiredindallas in post Re: Running wires in finished ceiling....
Do you have crown molding around t...
09-03-2019
11:17 PM - Estranged quoted Wiredindallas in post Re: Motion Sensor Switch
...with the neutral.Hi wiredindallas, I actually don't so...
04:03 PM - tomh1987 quoted Wiredindallas in post Re: Odd Voltage Reading (99VAC) in Master Bath
Is this receptacle on its own circ...
09-02-2019
06:40 PM - Lgb0250 quoted Wiredindallas in post Re: Motion sensor switch help
If you so choose, connect each mot...
08-31-2019
10:03 PM - user284 quoted Wiredindallas in post Re: Correct Wire Sheathing/Protection for Wires Entering Service
So you are concerned about the Rom...
08-29-2019
09:55 AM - FrodoOne quoted Wiredindallas in post Re: 24VAC 50VA transformers keep failing
If you can get to the wires enteri...
08-25-2019
12:38 AM - Norcal quoted Wiredindallas in post Re: Best wiring cable for concrete unfinished laundry room
If you are not planning on rocking...
12:12 AM - Norcal quoted Wiredindallas in post Re: RV trailer service hookup question
I agree with #6 wire and putting i...
08-24-2019
08:03 PM - More Power! quoted Wiredindallas in post Re: Conduit, De-Rating and My Solution: Legitimate?
Is that a 1-1/2" deep box with the...
02:26 PM - More Power! quoted Wiredindallas in post Re: Conduit, De-Rating and My Solution: Legitimate?
So what is the application for hav...
08-23-2019
09:31 AM - rjniles quoted Wiredindallas in post Re: RV trailer service hookup question
Separate colors (black, green and ...
08-12-2019
08:46 PM - Plasmech quoted Wiredindallas in post Re: Putting 200-amp fusible disconnect between meter box and service panel
Does your current main panel have ...
08-07-2019
09:18 PM - jbfan quoted Wiredindallas in post Re: Crimping grounds together
You may disagree and it may be in ...
12:27 PM - rjniles quoted Wiredindallas in post Re: Crimping grounds together
Glad I am not in Atlanta! I have ...



Top of Page | View New Posts