Wet bar


In my new house, the upper level game room will have a wet bar consisting of a small sink, about 3 feet of counter top, and some type of small refrigerator. The counter will have one duplex receptacle for what ever, and one duplex receptacle for the refrigerator. Would this be considered an appliance circuit and wired accordingly?
a7ecorsair is offline   Reply With Quote
Sponsored Links
Advertisement
 
Old 11-26-2010, 06:06 PM   #2
Master Electrician
 
Join Date: Mar 2010
Location: Indiana
Posts: 4,413
Rewards Points: 5,082
Default


As long as the refrigerator doesn't use more than 50% of the circuit rating a single circuit will suffice. I would recommend a 20 amp circuit. GFCI the countertop recep if it is within 6' of the sink.
brric is offline   Reply With Quote
Sponsored Links
Advertisement
 
Old 11-27-2010, 05:31 AM   #3
Member
 
Join Date: Mar 2007
Location: Eighty Four, Pa.15330
Posts: 1,597
Rewards Points: 1,192
Default


My new house would have 2 circuits in that senario.
bobelectric is offline   Reply With Quote
Sponsored Links
Advertisement
 
Old 11-27-2010, 08:24 AM   #4
Licensed Electrical Cont.
 
Speedy Petey's Avatar
 
Join Date: Feb 2004
Location: NY State
Posts: 7,828
Rewards Points: 2,006
Default


Quote:
Originally Posted by a7ecorsair View Post
Would this be considered an appliance circuit and wired accordingly?
It is NOT a kitchen, so the "small appliance" circuit rules do not apply. This should not matter though.
Listen to Brric and Bob.
Speedy Petey is offline   Reply With Quote
Old 11-27-2010, 08:43 AM   #5
I=E/R
 
a7ecorsair's Avatar
 
Join Date: May 2010
Location: Minnesota
Posts: 2,052
Rewards Points: 1,000
Default


OK, the small appliance rule is only for kitchens. The refrigerator will only be like 4 cu ft. so it wouldn't have that big of load.
Now I have two questions:
1) Would this circuit have to be Arc Fault protected or could I run it off a standard 20 amp breaker with a GFCI receptacle?
2) I'm going to run a separate circuit but..could these receptacles be on one of the circuits that is serving this upper level?
a7ecorsair is offline   Reply With Quote
Sponsored Links
Advertisement
 
Reply


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off





Top of Page | View New Posts