Rules on running boards?


I am running two 14/2 and one 12/2 cable. About 8 feet of it will be on the underside of joists. i have an old 8' piece of molding - can I use that as a running board? How do i attach the wires to it? Can I zip tie them to the bottom or side of it?
__________________
Andrew

secutanudu is offline   Reply With Quote
Sponsored Links
Advertisement
 
Old 04-23-2010, 07:33 AM   #2
the Musigician
 
DangerMouse's Avatar
 
Join Date: Jul 2008
Location: I'm right here!
Posts: 10,404
Rewards Points: 2,000
Default


Zip ties are fine, according to my inspector, or you can wrap with black tape and staple the underside to keep it from unwrapping with time and dryness.

Staple where you can, wrap the rest.

DM
Attached Thumbnails
Rules on running boards?-staples.jpg  
__________________
[SIGPIC][/SIGPIC]Click here to see some of my original magic tricks and trick boxes!
DangerMouse is offline   Reply With Quote
The Following User Says Thank You to DangerMouse For This Useful Post:
secutanudu (04-23-2010)
Sponsored Links
Advertisement
 
Old 04-23-2010, 09:09 AM   #3
Just call me Andrew
 
Join Date: Mar 2009
Location: Albany, NY
Posts: 2,271
Rewards Points: 1,032
Default


Can I just ziptie them to the underside of the board?
__________________
Andrew

secutanudu is offline   Reply With Quote
Sponsored Links
Advertisement
 
Old 04-23-2010, 09:54 AM   #4
the Musigician
 
DangerMouse's Avatar
 
Join Date: Jul 2008
Location: I'm right here!
Posts: 10,404
Rewards Points: 2,000
Default


Don't see why not, I like to secure every 12" or so, in case I or anyone ever needs to traffic the area, the wires will not snag anything.

DM
__________________
[SIGPIC][/SIGPIC]Click here to see some of my original magic tricks and trick boxes!
DangerMouse is offline   Reply With Quote
Old 04-23-2010, 10:06 AM   #5
Member
 
Join Date: Jun 2007
Posts: 4,109
Rewards Points: 308
Default


I would not have used running boards in your situation. I only use running boards when I am under the joist, not on top.
J. V. is online now   Reply With Quote
Old 04-23-2010, 10:08 AM   #6
Just call me Andrew
 
Join Date: Mar 2009
Location: Albany, NY
Posts: 2,271
Rewards Points: 1,032
Default


Quote:
Originally Posted by J. V. View Post
I would not have used running boards in your situation. I only use running boards when I am under the joist, not on top.
I will be running them under the joists (I assuming you were talking to DM).

Where in the NEC does it describe the use of running boards? I'd like to see what it has to say specifically just to fill my curiosity.
__________________
Andrew

secutanudu is offline   Reply With Quote
Old 04-23-2010, 10:29 AM   #7
the Musigician
 
DangerMouse's Avatar
 
Join Date: Jul 2008
Location: I'm right here!
Posts: 10,404
Rewards Points: 2,000
Default


LOL My pic is showing my RAFTER joists, not floor.....
it'd be kinda hard to put up my 5/8" Fire-X drywall had I put them on the underside!

DM
__________________
[SIGPIC][/SIGPIC]Click here to see some of my original magic tricks and trick boxes!
DangerMouse is offline   Reply With Quote
Old 04-24-2010, 11:44 AM   #8
Member
 
Join Date: Jun 2007
Posts: 4,109
Rewards Points: 308
Default


Quote:
Originally Posted by secutanudu View Post
I will be running them under the joists (I assuming you were talking to DM).

Where in the NEC does it describe the use of running boards? I'd like to see what it has to say specifically just to fill my curiosity.
Section 334.15(C)(A) NEC 2008
"Mike Holts Illustrated Guide to Changes to The NEC 2008" has some great pictures. I was lucky to have Chris Kennedy give me a copy. Real good guy. Check figure 334-1.
J. V. is online now   Reply With Quote
The Following User Says Thank You to J. V. For This Useful Post:
secutanudu (04-24-2010)
Sponsored Links
Advertisement
 
Reply


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
Gate post ledger boards Klawman Building & Construction 5 04-14-2010 01:22 AM
Chicago Conduit Rules Wrigleyville Electrical 6 01-28-2010 06:49 PM
running boards for electrical in unfinished basement paulyg Carpentry 2 01-26-2010 09:21 PM
hardwood flooring boards matjone Flooring 4 02-01-2008 05:35 PM
taco 700 constantly running.... drizzyboy HVAC 3 11-27-2007 07:03 AM




Top of Page | View New Posts