DIY Chatroom Home Improvement Forum - View Profile: ritelec
Advertisement


Go Back   DIY Chatroom Home Improvement Forum > Members List

CLICK HERE AND JOIN OUR COMMUNITY TODAY...IT'S FREE!

ritelec ritelec is offline

Member

Statistics

Total Posts
Blog
Total Thanks
General Information
  • Last Activity: Yesterday 09:14 PM
  • Join Date: 08-30-2009
  • Referrals: 0

Mentions

No results to display...

Quotes

06-29-2015
04:11 PM - FoMoCo65 quoted ritelec in post is this a single pole? Tryin to add a dimmer switch
pull the black/white/red out...
02:19 PM - ritelec quoted InPhase277 in post in ground pool bonding
The code requires the bond grid...
02:11 PM - InPhase277 quoted ritelec in post in ground pool bonding
If the bond grid is bonded i...
02:03 PM - ritelec quoted concrete_joe in post in ground pool bonding
stick a hot leg onto a gnd'd pool...
02:03 PM - ritelec quoted InPhase277 in post in ground pool bonding
stick a hot leg onto a gnd'd po...
01:39 PM - tylernt quoted ritelec in post PiG tail repair of double lugged circuits
what does afci have to do wi...
01:38 PM - ritelec quoted tylernt in post PiG tail repair of double lugged circuits
Also, I've never seen a half...
06-28-2015
10:22 AM - ritelec quoted jodym in post need some advice..........
the power is on because at...
09:44 AM - ritelec quoted Msradell in post 2014 nec code book
If you are doing a panel repl...
06-26-2015
09:16 PM - InPhase277 quoted ritelec in post in ground pool bonding
Thanks for that. I'm not...
03:43 PM - stickboy1375 quoted ritelec in post in ground pool bonding
Sir Stick,Phase and Jump, If...
03:00 PM - ritelec quoted stickboy1375 in post in ground pool bonding
680.26 (B) Bonded Parts. The pa...
06-24-2015
10:18 AM - ritelec quoted mm11 in post Hanging lights with a "fixed" canopy on a sloped ceiling
http://www.garvinindustri...
10:17 AM - ritelec quoted SCRealtor in post Hanging lights with a "fixed" canopy on a sloped ceiling
Excuse me if I don't use corre...
09:37 AM - ritelec quoted stickboy1375 in post in ground pool bonding
we are just masking the problem, ...
06-22-2015
06:45 PM - ritelec quoted stickboy1375 in post Bonding pool handrail
What the **** are you talking abo...
06-19-2015
08:42 AM - busman quoted ritelec in post Removing drop-in range - wiring?
yep, your right………..unless r...
08:19 AM - ritelec quoted busman in post Removing drop-in range - wiring?
Noalox is not required. Th...
05:02 AM - busman quoted ritelec in post Removing drop-in range - wiring?
:- ). Or nolox?? Noalox i...
01:53 AM - Jump-start quoted ritelec in post Removing drop-in range - wiring?
??? Is it me. Or do I not s...



Top of Page | View New Posts