DIY Chatroom Home Improvement Forum - View Profile: Jim Port
Advertisement


Go Back   DIY Chatroom Home Improvement Forum > Members List


CLICK HERE AND JOIN OUR COMMUNITY TODAY...IT'S FREE!

Jim Port Jim Port is online now

Licensed electrician

About Me

  • About Jim Port
    How did you find DIYChatroom.com?
    contractortalk.com
    Location
    Maryland
  • Signature
    Answers based on the National Electrical Code. Local amendments may apply. Check with your local building officials.

Statistics

Total Posts
Blog
Total Thanks
General Information
  • Last Activity: Today 08:54 PM
  • Join Date: 09-20-2007
  • Referrals: 0

Friends

Showing Friends 1 to 6 of 6

Mentions

No results to display...

Quotes

07-27-2016
07:14 PM - icandousa quoted Jim Port in post Re: Maximum Breaker Size for Subpanel?
Check the bus stab limits to ...
02:23 PM - brric quoted Jim Port in post Re: sub-panel and bonding
The OP has a 3 wire feeder to...
07-25-2016
04:51 PM - brric quoted Jim Port in post Re: sub-panel and bonding
The neutral bar is only bonde...
07-24-2016
11:53 PM - Tom738 quoted Jim Port in post Re: Old House Electrical Debacle
The buyer cannot make you cha...
07-21-2016
06:27 PM - jbfan quoted Jim Port in post Re: How do i remove this can?
Is that a drop ceiling? Lo...
07-20-2016
05:01 PM - Jim Port quoted Californiadecks in post Re: No earth ground on electrical panel
I'm licensed to do any trade I want ...
10:40 AM - Californiadecks quoted Jim Port in post Re: No earth ground on electrical panel
The bond has nothing to do w...
07-19-2016
10:16 AM - FrodoOne quoted Jim Port in post Re: Do they make a 220 Nema adapter?
Why are you encouraging someo...
08:26 AM - Jim Port quoted FrodoOne in post Re: Do they make a 220 Nema adapter?
However, while Speedy Petey c...
07-18-2016
04:17 AM - Jim Port quoted Californiadecks in post Re: No earth ground on electrical panel
pool equipment here has there own gr...
07-17-2016
11:37 PM - Californiadecks quoted Jim Port in post Pool grounded?
Pools should not have ground ...
10:27 PM - aftp302 quoted Jim Port in post Re: GE Panel Knockouts and NM Clamp Questions
Compare the KO to the locknut...
09:31 PM - Jim Port quoted Californiadecks in post Re: No earth ground on electrical panel
Cable guy doesn't need to tie to the...
09:28 PM - Jim Port quoted Californiadecks in post Re: No earth ground on electrical panel
Nope. It needs to be in the ground. ...
09:27 PM - aftp302 quoted Jim Port in post Re: GE Panel Knockouts and NM Clamp Questions
I see 4 unused 1/2" KO's on t...
09:26 PM - Jim Port quoted Californiadecks in post Re: No earth ground on electrical panel
Equipment can have its own secondary...
09:20 PM - Jim Port quoted rjniles in post Re: GE Panel Knockouts and NM Clamp Questions
Install a large 18" of PVC c...
07-16-2016
06:18 PM - CondoOwner16 quoted Jim Port in post Re: Trouble with replacing GFCI outlet
You should connect it like th...
07-15-2016
09:36 PM - BlueBSH quoted Jim Port in post Re: voltage on ground?
Your ground rods outside have...
10:16 AM - ETD66SS quoted Jim Port in post Re: Anatomy of a meter pedestal
Your power company should hav...



Top of Page | View New Posts

 

Search Engine Friendly URLs by vBSEO 3.6.1