Shed roof


I am in the planning phases on an addition and have some questions about the roof. It is approximately 5'x' in size and is a shed roof. It will abutt an existing brick wall both on two sides, along the back and along one of the sides. The architect is calling for a 2/12 slope. I have a couple of questions as I will be doing the install myself.

1) I have checked and it seems as though there are asphalt shingles approved for a 2/12 slope. I understand this is a low slope, is there anything I can/should do to ensure a quality install that will last?

2) What type of flashing and method is used where the roof attaches to the house in the back?

3) I know that along the side where the roof abutts the house, step flashing is used. This is a two part system, correct? Step flashing is installed with the singles and then counter flashing is installed over the step flashing, right?

4) The side opposite the step flashing runs right along the property line and is above my nieghbor's landing. I'd like to minimize the amount of water that drops from my roof down to his. Is there some form of drip edge or other flashing that can be installed, rather than allowing the shingles to just run over the edge?

Thanks!

stubits is offline   Reply With Quote
Old 07-14-2009, 07:48 PM   #2
Member
 
Join Date: Nov 2008
Location: Northern Maryland
Posts: 46
Default

Shed roof


I have been researching this same topic. It seems that there are two ways of doing it. One being to take a diamond blade on a grinder and cut a narrow slit in the existing brick and install what is called a reglet. This is how they transition from a parapet to the roof in those applications. Anyway, you then bend some flashing on a break so that about one inch actually embeds in that groove that you cut. You then seal the top of that joint with a bead of good roofing cement. I am still trying to figure out a few details like do I need to set this flashing in mortar in that slit and do I counter flash.

The other way they do it is to just laminate the flashing directly to the brick without cutting that channel and ducking the drip edge in there.

Justin08 is offline   Reply With Quote
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
Tie a shed roof into existing 6/12 roof jj1122_2000 Building & Construction 1 02-18-2009 09:37 PM
Flat roof questions, advice, ballpark estimate JerryH Roofing/Siding 18 11-07-2008 04:08 PM
Venting a shed roof with 2/12 slope atulc Roofing/Siding 5 08-25-2006 07:28 AM




Top of Page | View New Posts

Copyright © 2003-2014 Escalate Media. All Rights Reserved.