Room Leaking from chimney somewhere help please


I have leak coming down into my basement and I believe it has something to do with either the chimney chase cover or the area area where the chimney meets the house. Any help would be greatly appreciated.
Attached Thumbnails
Room Leaking from chimney somewhere help please-20130310_144942.jpg   Room Leaking from chimney somewhere help please-20130310_145001.jpg   Room Leaking from chimney somewhere help please-20130310_145302.jpg  

sicnic is offline   Reply With Quote
Old 03-10-2013, 07:51 PM   #2
Member
 
Join Date: Nov 2011
Location: Hartfield VA
Posts: 25,560
Default

Room Leaking from chimney somewhere help please


First thing I see is the cap was not made big enough.
Looks like water can get in under the J moulding and outside corner.
Really need to get up on the roof to look at the whole cap and flashing set up.

joecaption is offline   Reply With Quote
The Following User Says Thank You to joecaption For This Useful Post:
tinner666 (03-10-2013)
Old 03-10-2013, 08:59 PM   #3
Pro Slate Roofer
 
tinner666's Avatar
 
Join Date: Mar 2005
Location: Richmond, Va.
Posts: 1,580
Default

Room Leaking from chimney somewhere help please


Looks like Joe nailed it. Probably not wrapped with WRB either.
tinner666 is offline   Reply With Quote
Old 03-10-2013, 09:25 PM   #4
Member
 
Join Date: Nov 2011
Location: Hartfield VA
Posts: 25,560
Default

Room Leaking from chimney somewhere help please


WRB?
House wrap?
joecaption is offline   Reply With Quote
Old 03-11-2013, 06:11 AM   #5
Pro Slate Roofer
 
tinner666's Avatar
 
Join Date: Mar 2005
Location: Richmond, Va.
Posts: 1,580
Default

Room Leaking from chimney somewhere help please


Quote:
Originally Posted by joecaption View Post
WRB?
House wrap?
Water Resistent Barrier. Since chimneys are often not considered a part of the building envelope, I often see the plywood is the only thing behind the siding. No wrap at all.
tinner666 is offline   Reply With Quote
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
Isolated Room in Basement - Theater Room EricWindow HVAC 8 11-24-2012 03:19 PM
help with leaking chimney dartman92 Concrete, Stone & Masonry 3 03-06-2012 04:11 PM
Well Room (Cold Room) Issue--Advice Needed TomPgh Building & Construction 11 01-03-2011 06:31 PM
Leaking water into under-garage storage room phauck Building & Construction 5 01-01-2011 06:39 AM
hello , i have a leaking balcony over a room amanda everson General DIY Discussions 3 10-03-2009 09:48 PM




Top of Page | View New Posts

Copyright © 2003-2014 Escalate Media. All Rights Reserved.