Originally Posted by Greg Shubert View Post
What daylight. I sent pics. Is just stubbed up above roof and they put a typical box attic vent over it. What is a storm collar?
thats not the issue i can see that ...the problem is your new roof...what type of flashing is needed for the pipe to exit roof ..this boot the metal guy sold you....just what is it Iam not a mind reader..my guess nobody else is either....wait for some other takers...

ben's plumbing is offline   Reply With Quote
Old 01-03-2012, 08:20 PM   #17
Newbie
 
Join Date: Jan 2012
Posts: 18
Default

Range vent in new exposed fastener metal roof


The only boots I have ever seen sold for metal roofing. They are rubber with a bendable strip along the bottom that you form around the ridges and flats of the roofing. It is stepped on top and you cut it to the diameter needed
Greg Shubert is offline   Reply With Quote
Old 01-03-2012, 08:22 PM   #18
Newbie
 
Join Date: Jan 2012
Posts: 18
Default

Range vent in new exposed fastener metal roof


AAs for a mind reader.. I think I would have went to another site for that. Im an electrician not a roofer.
Greg Shubert is offline   Reply With Quote
Old 01-03-2012, 08:24 PM   #19
Newbie
 
Join Date: Jan 2012
Posts: 18
Default

Range vent in new exposed fastener metal roof


AAs for flashing... I've seen a hundred of these roofs put on. No one flashes anything. They BOOT them
Greg Shubert is offline   Reply With Quote
Old 01-03-2012, 08:25 PM   #20
Newbie
 
Join Date: Jan 2012
Posts: 18
Default

Range vent in new exposed fastener metal roof


Guess an electrician and a plumber dont make very good roofers
Greg Shubert is offline   Reply With Quote
Old 01-03-2012, 08:34 PM   #21
Member
 
Join Date: Nov 2011
Location: Hartfield VA
Posts: 26,168
Default

Range vent in new exposed fastener metal roof


Not going to want to hear it but the pipe extentions, proper rain cap, and cap, PVC you will need to extend the sewer vents and all the roof boots should have been figured out, bought and on site before starting the roof. Not a whole lot of places may stock what your going to need.
If that pipe for the vent is round then you need a mushroom cap.
A rain cap is a piece that goes arounfd the pipe to devert the rain from running down the side of the pipe and getting in under the roof boot.
Metal roof takes a special type of boot a good one will have a metal band around the outside where the screws go. HD and Lowes do not sell them.
http://www.bestmaterials.com/silicon...-boot-684.html
http://www.nextag.com/roof-vent-cap/compare-html

Last edited by joecaption; 01-03-2012 at 08:41 PM.
joecaption is offline   Reply With Quote
Old 01-03-2012, 08:39 PM   #22
Newbie
 
Join Date: Jan 2012
Posts: 18
Default

Range vent in new exposed fastener metal roof


I have the boots you are talking about. I also have the stuff for the pvc. Just not the range hood. No one can tell me exactly what I need. I guess I can go get on a roof tomorrow and look.... Hopefully
Greg Shubert is offline   Reply With Quote
Old 01-03-2012, 08:43 PM   #23
Newbie
 
Join Date: Jan 2012
Posts: 18
Default

Range vent in new exposed fastener metal roof


I mean every hillbilly within miles has done it. Can't be a huge deal.
Greg Shubert is offline   Reply With Quote
Old 01-03-2012, 08:44 PM   #24
Member
 
Join Date: Nov 2011
Location: Hartfield VA
Posts: 26,168
Default

Range vent in new exposed fastener metal roof


So is you plan to just install the metal roofing directly over this shingled roof?
joecaption is offline   Reply With Quote
Old 01-03-2012, 08:44 PM   #25
Member
 
Join Date: Oct 2011
Location: pa
Posts: 4,287
Default

Range vent in new exposed fastener metal roof


Quote:
Originally Posted by Greg Shubert View Post
AAs for flashing... I've seen a hundred of these roofs put on. No one flashes anything. They BOOT them
you call it a boot i call it a flashing same thing..... the problem remains you don't have the proper boot that you need.....
ben's plumbing is offline   Reply With Quote
Old 01-03-2012, 08:48 PM   #26
Newbie
 
Join Date: Jan 2012
Posts: 18
Default

Range vent in new exposed fastener metal roof


Quote:
Originally Posted by ben's plumbing View Post
you call it a boot i call it a flashing same thing..... the problem remains you don't have the proper boot that you need.....
What do i need then?

I have the boots that have the metal ring around the base. Just no way to cap it..

And no. I am taking shingles off and new underlayment. Said I was a hillbilly not stupid.
Greg Shubert is offline   Reply With Quote
Old 01-03-2012, 08:50 PM   #27
Member
 
Join Date: Oct 2011
Location: pa
Posts: 4,287
Default

Range vent in new exposed fastener metal roof


you were told what you need bring pipe up through roof....put YOUR BOOT ON IT....what is the issue..the top... what type of pipe are you using to extend exhaust pipe...then you get the top to match.....did we miss something...
ben's plumbing is offline   Reply With Quote
Old 01-03-2012, 11:01 PM   #28
Doing This Way Too Long
 
Join Date: Jun 2008
Location: North Idaho
Posts: 1,119
Default

Range vent in new exposed fastener metal roof


Can't find any pictures so will try to describe it.
That vent needs to come off and you should have a pipe underneath it. You need to match up to that and add an extension to it. Shoot for at least 18" above the roofdeck. You can also get a china cap to mount on top of the new pipe but don't put it on yet.

Install the metal roof, cutting around the pipe doesn't need to be perfect but the base of your flashing (odds are it's a masterflash or oatey, unless it's grey then it's probably a dektite) needs to cover the entire hole. Once roof is installed, Install the flashing with a small bead of urethane caulk (NOT SILICONE) forming it neatly to the contour of the roof. Press snugly on all crotches and install a screw within 5/8" of the crotch. Fasten the rest of the boot approx every 1 1/2" snugging the screws until the boot compresses under it. DO Not overdrive them. It's best to hose clamp and caulk the top of the boot to the pipe. If you don't have one big enough join two together.

Now install your china cap or whatever cap you got on the top of the new pipe and you are done.

Hope this helps

BTW hope your pipe does not span two ribs or you will end up with a dam behind the pipe. Then it gets much more difficult.

Last edited by OldNBroken; 01-03-2012 at 11:03 PM.
OldNBroken is offline   Reply With Quote
Old 01-04-2012, 08:25 AM   #29
Member
 
Join Date: Nov 2011
Location: Hartfield VA
Posts: 26,168
Default

Range vent in new exposed fastener metal roof


Is this the style roofing your installing?
http://www.unioncorrugating.com/5v.html

joecaption is offline   Reply With Quote
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
Multi rib metal roof on double wide...static vents wpilotm Roofing/Siding 0 09-10-2011 03:51 PM
Best roof cap for range hood vent bsperr HVAC 0 08-05-2010 02:33 PM
venting from mobile home through new metal roof jeanmoon Roofing/Siding 2 07-27-2010 08:39 PM
Metal Roof vent pipe flashing vtboy51 Roofing/Siding 2 05-10-2010 06:21 PM
Tired of patching my flat garage roof, I want to reroof it. Metal???? sellingitall Roofing/Siding 2 09-12-2008 08:51 PM




Top of Page | View New Posts

Copyright © 2003-2014 Escalate Media. All Rights Reserved.