Old 01-04-2006, 04:02 PM   #1
Newbie
 
Join Date: Jan 2006
Posts: 3
Rewards Points: 10
Default

Illogical theory? plywood of planks


Am I totally off the wall with this concept? I am going to replace my roof which has 5 1/2" planks in place with 4 1/4" spaces between the planks. Code requires a solid suface on replacing the shingles. I figure I already have almost 60 % of the roof covered with planks. How illogical is it to fill in the spaces with 4 1/4" planks instead of a solid plywood overlay?
Just filling in the spaces with five 20 foot 1X4s is almost equal to 2 1/2 sheets of plywood and easier to handle. The 4 1/4" spaces are consistent. I do not see anyone else doing this so am I getting into something I will regret.

Advertisement


Last edited by rl10851; 01-04-2006 at 04:24 PM.
rl10851 is offline   Reply With Quote
Old 01-04-2006, 04:51 PM   #2
Commercial Roofing
 
AaronB's Avatar
 
Join Date: Jan 2005
Location: Illinois
Posts: 927
Rewards Points: 500
Default

Illogical theory? plywood of planks


I have seen it done, nver done it myself. Is it more cost effective? Plywood would be a smoother surface. What lumber comes in dimension 4.5""?

Advertisement

__________________
www.roseroofing.net/ Free inspection within 12 miles
Seamless Polyurea Roofing Membranes for Metal Roofing, Roof Leak Repair, Seamless Commercial Spray Foam Insulation, Seamless Commercial Roofing, SPF Roofing, Industrial Insulation, Our trucks are red but our roofing is GREEN!
AaronB is offline   Reply With Quote
Old 01-04-2006, 06:42 PM   #3
Member
 
Join Date: Aug 2005
Posts: 253
Rewards Points: 250
Default

Illogical theory? plywood of planks


Too many cracks and the nails will pop through and break the shingle. I just went through this on a 3/12 where the original boards were tight but shrunk and left 1/8 in.+ gaps and the nails breaking the shingle was the cause of the multiple leaks. I think it was Aaron or one of the guys around here that clued me into the problem. Granted mine was a 3/12 but i vote resheath the roof and have less problems for many years to come. <P>

I also started one of those fill in projects back in the 70's. After about an hour of ripping boards we went and bought a pile of plywood and did it right in 1/10 the time. HS.
K2eoj is offline   Reply With Quote
Old 01-04-2006, 07:00 PM   #4
Contractor
 
Join Date: Feb 2004
Location: Jensen Beach, FL
Posts: 835
Rewards Points: 500
Default

Illogical theory? plywood of planks


You don't give the rafter distance but if you're on 24", even a 4-1/2" board with a knot in it could be pretty weak. Here, most board sheathing is T&G and what you are refering to very old buildinds and sheds. I'd deck it over as said before.
Teetorbilt is offline   Reply With Quote
Old 01-04-2006, 10:04 PM   #5
renovations
 
Join Date: Aug 2005
Location: Canada
Posts: 430
Rewards Points: 250
Default

Illogical theory? plywood of planks


If you're putting arch. lam. shingles (or 3 tabs) on you've got to put ply (or OSB) down for the warranty, no? I've replaced roofs that were shingled over boards after only a few years, the shingles were all cracking at the seams between the boards.
Bonus is offline   Reply With Quote
Old 01-04-2006, 11:16 PM   #6
Contractor
 
Join Date: Feb 2004
Location: Jensen Beach, FL
Posts: 835
Rewards Points: 500
Default

Illogical theory? plywood of planks


Sorry, I forgot about the expansion/contraction aspect. Go sheathing and be done.
Teetorbilt is offline   Reply With Quote
Old 01-05-2006, 06:11 AM   #7
Commercial Roofing
 
AaronB's Avatar
 
Join Date: Jan 2005
Location: Illinois
Posts: 927
Rewards Points: 500
Default

Illogical theory? plywood of planks


It does not need to be plywood. You simply need a tightly butted roof deck. I have torn off 40 year old asphalt shingle roofs on plank that were in pretty good shape, all things considered. Shingles cracking like that most likely had another source of destruction.

Advertisement

__________________
www.roseroofing.net/ Free inspection within 12 miles
Seamless Polyurea Roofing Membranes for Metal Roofing, Roof Leak Repair, Seamless Commercial Spray Foam Insulation, Seamless Commercial Roofing, SPF Roofing, Industrial Insulation, Our trucks are red but our roofing is GREEN!
AaronB is offline   Reply With Quote
Reply


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
DIY Chair mat from plywood and carpet tiles jbwaechter Flooring 3 08-20-2009 07:29 AM
Plywood Wall Sheathing? sandyman720 Building & Construction 13 08-02-2007 09:02 PM
Exterior plywood, not secured well enough mt232 Building & Construction 4 07-03-2007 10:34 AM
Exterior plywood mt232 Building & Construction 1 06-25-2007 09:59 AM
Backer board vs. plywood for tile underlayment allpraisebob Flooring 4 01-07-2007 08:44 PM




Top of Page | View New Posts