My house is located on Long Island NY, built 1950. I am replacing the vent ceiling vent fan in our first floor Bathroom.Existing joist is 1-1/2"x 7" exact. Seems to be typical for this era. Unit from NuTone designed for 2"x8" nominal joist. Sheetrock is 3/8".
Have not purchased anything yet but thought this model, QTN 80E would work well.

I guess there would be some of the fan housing exposed. Not sure if cover will fit flush.

Any advise is appreciated.

Advertisement


Last edited by Peterrabit; 05-25-2013 at 10:16 AM.
Peterrabit is offline   Reply With Quote
Old 05-24-2013, 02:24 PM   #2
Member
 
Join Date: Nov 2011
Location: Hartfield VA
Posts: 27,778
Rewards Points: 672
Default

first floor bath vent fan


3/8 on a ceiling
If you set the bottom of the box even with the sheetrock it will still work.

Advertisement

__________________
When posting in forums, letting us know your location will help others give better feedback/advice/solutions to your questions
joecaption is online now   Reply With Quote
Old 05-25-2013, 10:24 AM   #3
Newbie
 
Peterrabit's Avatar
 
Join Date: May 2013
Location: Long Island New York
Posts: 2
Rewards Points: 10
Default

first floor bath vent fan


Thanks joecaption.
I have edited my post to include details. Yes 3/8" is all through this house. I'm thinking it would be wise to go over it with 3/8 or 1/2". I think that would give a proper fit to the fan.
Peterrabit is offline   Reply With Quote
Old 05-25-2013, 02:51 PM   #4
Registered User
 
Join Date: Mar 2009
Posts: 9,993
Rewards Points: 2,052
Default

first floor bath vent fan


Agreed, cannot texture water based with 3/8", see footnote "d"; http://publicecodes.cyberregs.com/ic...002_par010.htm

Gary
PS Welcome to the forums!
__________________
If any ads are present in my answer above, I do not condone/support/use the product or services listed, they are there against my permission.
Gary in WA is offline   Reply With Quote
Reply


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
New Roof marknok Roofing/Siding 4 08-06-2011 12:41 PM
Water Heater Vent Question pd417 Plumbing 1 05-15-2010 01:34 PM
finishing a basement bath - tie in to ejector pump vent? ajbowman Plumbing 7 04-15-2008 01:09 AM
Where is the toilet vent?!?!? domgbrown Plumbing 4 01-11-2008 07:33 PM
Yoke vent for water closet kenlog Plumbing 4 07-13-2007 07:34 PM




Top of Page | View New Posts