Replace main stack, how far down to go


The main stack in the house I just bought is cast, everything leading up to it has been replaced with PVC. I'd like to replace the stack with PVC as well, since I'm adding a basement washer/dryer, and plan to add a sink and toilet as well. I figure since I have to cut it up anyway, replace it all and get rid of all the adapters in there.

It's probably the simplest setup I've ever seen. It's a ranch, stack is right below bathroom. Toilet sits on top, sink appears to run into the vent pipe, and kitchen sink and tub are on a line coming in as well. I'm just wondering how far down I can/should cut the pipe. I don't want to get into tearing out concrete right now, so something above floor level. It has a cleanout right at the floor, should I cut below or leave that and cut right above it? Like I said, I want to add a toilet down there at some point, so I need to be able to Y into it as low as possible. Here are some pics. Any/all help and advice is appreciated!





supaphly42 is offline   Reply With Quote
Old 07-10-2012, 06:07 PM   #2
moderator
 
TheEplumber's Avatar
 
Join Date: Jul 2010
Location: Idaho
Posts: 6,546
Default

Replace main stack, how far down to go


For the CW and sink you can cut the stack a few inches above the hub and convert to plastic by using a Pl x ci shielded coupling.
Use a 4x2 tee to run horz. to your new fixture location.
Then vent the new fixtures. Also, that existing stack is extremely heavy so support it well when you chop into it. They're known to come crashing down
If your PVC is right outside, consider breaking the floor out, tunnel under the footing and replacing all the cast.
Also, Is that a toilet flange next to the stack?

__________________
When posting in forums, letting us know your location will help others give better feedback/advice/solutions to your questions
TheEplumber is online now   Reply With Quote
Old 07-10-2012, 07:22 PM   #3
Newbie
 
Join Date: Jul 2012
Posts: 4
Default

Replace main stack, how far down to go


I actually have no idea what that is in the floor next to it. Haven't tried to look down in. There's a cap, but it wasn't screwed on, flipped upside down and just sitting there. That would be handy if it's an old flange. And no clue what's under the floor or out to the road, could all be cast as well.

Thanks for the info. The top chunks are all strapped to the joists, but that one long piece isn't held up by anything. Definitely gonna be a brute.
supaphly42 is offline   Reply With Quote
Old 07-10-2012, 07:23 PM   #4
MarginallyQualified
 
Join Date: Dec 2011
Location: Winston-Salem NC
Posts: 3,647
Default

Replace main stack, how far down to go


Quote:
Originally Posted by supaphly42 View Post
...since I'm adding a basement washer/dryer, and plan to add a sink and toilet as well.
Until you're ready to do the sink and toilet floor work leave the rest alone.
The washer drain can be adapted into the TEE at the bottom of the stack for now.
TarheelTerp is offline   Reply With Quote
Old 07-10-2012, 07:37 PM   #5
Newbie
 
Join Date: Jul 2012
Posts: 4
Default

Replace main stack, how far down to go


Quote:
Originally Posted by TarheelTerp View Post
Until you're ready to do the sink and toilet floor work leave the rest alone.
The washer drain can be adapted into the TEE at the bottom of the stack for now.
Hmm, good point. Would certainly make it so we can do laundry much quicker/easier! We've lived here for a week yesterday, and after moving, laundry is piling up pretty good, haha.

Also, here's a close-up of that other drain in the floor and the cap. Does it seem like a flange? And might it still be usable?

supaphly42 is offline   Reply With Quote
Old 07-10-2012, 10:58 PM   #6
Member
 
Join Date: Aug 2010
Posts: 1,526
Default

Replace main stack, how far down to go


Quote:
Originally Posted by supaphly42 View Post
Also, here's a close-up of that other drain in the floor and the cap. Does it seem like a flange? And might it still be usable?


Definitely a toilet flange. Usable? Only a camera pipe inspection can tell for sure.
VIPlumber is offline   Reply With Quote
Old 07-11-2012, 07:39 AM   #7
Newbie
 
Join Date: Jul 2012
Posts: 4
Default

Replace main stack, how far down to go


Gotcha. I'll have to look into that when it's time to add the toilet in and have someone check it out. Would certainly save a lot of work.

supaphly42 is offline   Reply With Quote
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
Remove/Replace cast iron Y main drain and replace with ABS? graysqwrl Plumbing 5 06-17-2011 05:44 PM
Main stack issue Elka Plumbing 3 10-14-2009 10:17 PM
Replace main panel? And lots of other ?s Bcoleman6 Electrical 13 01-22-2008 09:40 AM
main lug vs main breaker for sub panel diyll Electrical 1 01-17-2008 08:18 PM
DWV Stack Question dcgray2 Plumbing 9 07-14-2006 12:56 PM




Top of Page | View New Posts

Copyright © 2003-2014 Escalate Media. All Rights Reserved.