marty813 09-24-2013 09:28 AM

Ran out of pitch for drain line
 
I recently hacked up 15 feet of concrete to run a new drain line for a bathroom I will be installing. I started from the main stack and run the 4" pvc from there, by the time I reached the toilet, I am about a half inch to high once I put the flange into the 90. I was wondering if anybody ever cut the 90 back so that the flange could slide further down into the 90?

broox 09-24-2013 09:40 AM

If it is really only 1/2 inch, you should be fine, go ahead and cut it. Anchor the flange to the concrete.

plumberinlaw 09-24-2013 01:25 PM

you could run 3" pipe instead

Ghostmaker 09-24-2013 07:03 PM

Use a 4 by 3 coupling run the toilet and vent in 3 inch... Vent that thing that allows stuff to have air...

ben's plumbing 09-24-2013 10:10 PM

Quote:

Originally Posted by marty813 (Post 1245868)
I recently hacked up 15 feet of concrete to run a new drain line for a bathroom I will be installing. I started from the main stack and run the 4" pvc from there, by the time I reached the toilet, I am about a half inch to high once I put the flange into the 90. I was wondering if anybody ever cut the 90 back so that the flange could slide further down into the 90?

yes we have cut hubs before...but I don't reccomend it ..as mentioned reduce to 3" it should just make it..ben sr