Question on Venting


I'm pretty sure I am going to have to hurt someone! I had some plumbing done for my bathroom remodel since I have been working to much and needed to get it completed.

He finished yesterday and I had time to go review the work today. Correct me if I am wrong but unless something changed recently...Terminating the vent pipe in the crawl space is no bueno right?

Also, would using an AAV off a dual sink and putting it in the wall cavity also be incorrect?

REXAMUS is offline   Reply With Quote
Old 09-12-2012, 03:40 PM   #2
Member
 
Join Date: Jul 2011
Location: NORTH CAROLINA
Posts: 135
Default

Question on Venting


Some pictures...
Attached Images
  

REXAMUS is offline   Reply With Quote
Old 09-12-2012, 07:20 PM   #3
moderator
 
TheEplumber's Avatar
 
Join Date: Jul 2010
Location: Idaho
Posts: 6,863
Default

Question on Venting


That doesn't look like a vent. Is that a san tee behind it? That would be the vent and the 90 appears to be a toilet bend- ready for a flange at the floor line. I'm guessing 3" pipe..
As for the AAV- I very seldom use them and I don't put them in the wall without a louvered access panel.
What has the plumbing inspector said- there is a permit right?
__________________
VOTE NOW!
When posting in forums, letting us know your location will help others give better feedback/advice/solutions to your questions
TheEplumber is offline   Reply With Quote
Old 09-12-2012, 08:07 PM   #4
Member
 
Join Date: Jul 2012
Location: NJ
Posts: 377
Default

Question on Venting


Where I live, AAV cannot be enclosed behind a wall at all.

Also, I am not a pro but I am pretty sure it is not a generally accepted practice to mount waste pipes on a stack of left over 2x4.

Hope you did not pay the guy yet? I would ask him to pull a permit and fix and bring everything up to code.

ps. I haven't dealt too much with pex, but shouldn't those stub outs be supported by a blocking of some sort as pex tubing does not offer structural rigidity, unlike a copper tubing?

Last edited by allthumbsdiy; 09-12-2012 at 08:10 PM. Reason: added a statement about pex stubouts
allthumbsdiy is offline   Reply With Quote
Old 09-12-2012, 08:51 PM   #5
Doing it myself
 
Alan's Avatar
 
Join Date: Apr 2006
Location: Crescent City, CA
Posts: 3,750
Send a message via AIM to Alan Send a message via MSN to Alan
Default

Question on Venting


Quote:
Originally Posted by allthumbsdiy View Post
Also, I am not a pro but I am pretty sure it is not a generally accepted practice to mount waste pipes on a stack of left over 2x4.
While I would never do something like that, the code only says the piping has to be supported, not how it must be supported.




That looks like a friggin mess. AAV should be accessible if it MUST be used.


If that is a 90 left for a closet flange, I would think it would be temporarily capped or plugged...
__________________
Journeyman Plumber
Alan is offline   Reply With Quote
Old 09-12-2012, 09:11 PM   #6
Member
 
Join Date: Jan 2012
Location: ohio
Posts: 1,093
Default

Question on Venting


wow that is not a legal a a v since it has a spring in it and here you are allowed to put in wall as long as it is accessible and breathable here is he i.r.c. on aav
http://publicecodes.cyberregs.com/ic...?bu2=undefined

also pex should be supported at sub outs

and no you can not just have open vent in crawl space

was this the plumber who name you found in a restroom stall
__________________
"be careful at listening to just one persons advise" said me
"be careful at listening to just one persons advise" said myself
p.s. not all i say is a fact but not all i say is my opinion.
jaydevries is offline   Reply With Quote
Old 09-12-2012, 09:16 PM   #7
Member
 
Join Date: Oct 2009
Posts: 37
Default

Question on Venting


First of all , a aav installed below the flood level of a basin is definitively

a no-no. This guy doesn't know what he is doing. The work in the other

picture looks amateurish too (IMHO). The top of the closet el isn't parallel

with the floor. Fit up might be an issue. Only takes a little time and some

knowledge to do the job right. I'd part ways with this guy.
LeakyMike is offline   Reply With Quote
Old 09-12-2012, 09:47 PM   #8
Member
 
Join Date: Aug 2010
Posts: 1,526
Default

Question on Venting


Water stub outs should look like this,



and AAVs must be accessible, usually behind a grill or access panel.

One question. What exactly is being vented in your crawlspace?

Last edited by VIPlumber; 09-12-2012 at 09:50 PM. Reason: Question.
VIPlumber is offline   Reply With Quote
Old 09-12-2012, 10:07 PM   #9
Master Plumber
 
Javiles's Avatar
 
Join Date: Dec 2011
Location: Miami Florida
Posts: 1,338
Default

Question on Venting


Wow you need to get someone that knows whats hes doing, lots of mistakes, along with multiple code violations poor workmanship. get rid of this clown!
__________________


Experience is Knowing what to do next, Skill is knowing how to do it

http://www.americandrain.net
Javiles is offline   Reply With Quote
Old 11-04-2012, 04:43 PM   #10
Member
 
Join Date: Jul 2011
Location: NORTH CAROLINA
Posts: 135
Default

Question on Venting


Quote:
Originally Posted by Javiles View Post
Wow you need to get someone that knows whats hes doing, lots of mistakes, along with multiple code violations poor workmanship. get rid of this clown!
Quote:
Originally Posted by VIPlumber View Post
Water stub outs should look like this,



and AAVs must be accessible, usually behind a grill or access panel.

One question. What exactly is being vented in your crawlspace?
Quote:
Originally Posted by LeakyMike View Post
First of all , a aav installed below the flood level of a basin is definitively

a no-no. This guy doesn't know what he is doing. The work in the other

picture looks amateurish too (IMHO). The top of the closet el isn't parallel

with the floor. Fit up might be an issue. Only takes a little time and some

knowledge to do the job right. I'd part ways with this guy.
Quote:
Originally Posted by jaydevries View Post
wow that is not a legal a a v since it has a spring in it and here you are allowed to put in wall as long as it is accessible and breathable here is he i.r.c. on aav
http://publicecodes.cyberregs.com/ic...?bu2=undefined

also pex should be supported at sub outs

and no you can not just have open vent in crawl space

was this the plumber who name you found in a restroom stall
Quote:
Originally Posted by Alan View Post
While I would never do something like that, the code only says the piping has to be supported, not how it must be supported.




That looks like a friggin mess. AAV should be accessible if it MUST be used.


If that is a 90 left for a closet flange, I would think it would be temporarily capped or plugged...
Quote:
Originally Posted by allthumbsdiy View Post
Where I live, AAV cannot be enclosed behind a wall at all.

Also, I am not a pro but I am pretty sure it is not a generally accepted practice to mount waste pipes on a stack of left over 2x4.

Hope you did not pay the guy yet? I would ask him to pull a permit and fix and bring everything up to code.

ps. I haven't dealt too much with pex, but shouldn't those stub outs be supported by a blocking of some sort as pex tubing does not offer structural rigidity, unlike a copper tubing?

I hate I forgot about this thread. I had completed the rest of the bathroom myself because I hate trusting others to do work. If it's going to be messed up I'd rather blame myself and still have money in my pocket.

Anywho..I managed to get some of the money back. Unfortunately the company had great reviews everywhere I looked but I guess I could have done a better job on looking at their past jobs.

I think the main problem is that a lot of people pay people like this to do things but don't know if it's right or wrong. I semi have a clue how things SHOULD be done but that doesn't mean I want to bother with doing it.

I've been busy the last couple of weeks but I'm going to get all the pex fixed this week and put copper stubouts at the vanity and shower. I am also going to finish removing all the AAVs and running the vent pipes out the roof. Thanks for all the input!!!
REXAMUS is offline   Reply With Quote
Old 11-05-2012, 09:14 AM   #11
Doing it myself
 
Alan's Avatar
 
Join Date: Apr 2006
Location: Crescent City, CA
Posts: 3,750
Send a message via AIM to Alan Send a message via MSN to Alan
Default

Question on Venting


Quote:
Originally Posted by LeakyMike View Post
First of all , a aav installed below the flood level of a basin is definitively

a no-no.
Depends on what code you're using. Our says minimum of 4" above the trap outlet.

__________________
Journeyman Plumber
Alan is offline   Reply With Quote
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
Another Venting Question rpratt84 Roofing/Siding 3 07-12-2012 03:17 PM
Dryer Venting Question jabond Appliances 2 06-21-2012 03:08 PM
Venting question Sammy 2 Plumbing 2 02-14-2011 08:57 PM
Question about dryer venting jimithing78 HVAC 10 08-26-2008 11:37 AM
Rheem classic 90 plus venting question jjconst07 HVAC 2 07-04-2008 05:14 PM




Top of Page | View New Posts

Copyright © 2003-2014 Escalate Media. All Rights Reserved.