Pressure drop after replacing faucet seat


I had a leaking faucet in a guest bathroom (tub/shower) and replaced the washer first; no dice.
I then replaced the seat because I noticed it had a fissure in the side. (to impress upon you my noobness, it took 2 days and 5 trips to the hardware store to even figure out what the seat was and why, after 3 washer replacements, it was still leaking)

Since then the water pressure is pathetic for that tub, everything else is fine so it's not the house in general. I've no idea what the old one was but the replacement is an American Standard #20 7/16" x 24 THD (I've only a marginal idea of what all that means).

It fit physically without issue, and I replaced the cold water side about 9 months ago with the same type (this last one was the hot water side). I guess I can't even be certain the cold water pressure was ok after the replacement since hot water in the tub is primary.

I don't know what information to provide that would be helpful. The people who built the house (custom home) seemed to know what they were doing (at least that's what the inspector said). So far everything I've found is standard sizing.

Thanks.

plumbing_noob is offline   Reply With Quote
Old 10-24-2010, 05:11 PM   #2
Member
 
Join Date: May 2010
Location: Rosedale,Md
Posts: 168
Default

Pressure drop after replacing faucet seat


Quote:
Originally Posted by plumbing_noob View Post
I had a leaking faucet in a guest bathroom (tub/shower) and replaced the washer first; no dice.
I then replaced the seat because I noticed it had a fissure in the side. (to impress upon you my noobness, it took 2 days and 5 trips to the hardware store to even figure out what the seat was and why, after 3 washer replacements, it was still leaking)

Since then the water pressure is pathetic for that tub, everything else is fine so it's not the house in general. I've no idea what the old one was but the replacement is an American Standard #20 7/16" x 24 THD (I've only a marginal idea of what all that means).

It fit physically without issue, and I replaced the cold water side about 9 months ago with the same type (this last one was the hot water side). I guess I can't even be certain the cold water pressure was ok after the replacement since hot water in the tub is primary.

I don't know what information to provide that would be helpful. The people who built the house (custom home) seemed to know what they were doing (at least that's what the inspector said). So far everything I've found is standard sizing.

Thanks.
Thing is that a lot of people don't know is that washers and seats are not the same even if they fit, both can cause your problem. The only thing I think you can do is pull the cold seat (IF IT'S WORKING O.K.) and match it EXACTLY and put it in the hot, if you have a flat type washer and the faucet calls for a cone shape that could be a problem also.

braindead is offline   Reply With Quote
Old 10-24-2010, 07:13 PM   #3
Newbie
 
Join Date: Oct 2010
Posts: 7
Default

Pressure drop after replacing faucet seat


I was talking about this with my wife today and she said the cold pressure dropped after the replacement of the seat some 9 months ago, but it just didn't matter as much as the hot, which was working fine.

The original seat (no longer have them) was flat where it hit the washer but the new one, at least the hot, is semi-circled. That may be what is causing the knob turns to be different, from what my wife explained.

I suspect I just have the wrong seats for these faucets and will take the box to Home Depot this week and look for something that matches the threaded side but is flat and has a larger hole.

For my edification, if the seat box says
20
7/16" x 24 THD

Which of these means what? I'm guessing the 7/16" references the inside-pipe thread portion but I've no idea what the 20 or 'x 24 THD' means.

Thanks.
plumbing_noob is offline   Reply With Quote
Old 10-25-2010, 12:02 AM   #4
Member
 
Join Date: Aug 2010
Posts: 601
Default

Pressure drop after replacing faucet seat


the 24 refers to the number of threads per inch. if the seat easily screwed in then it is correct. the 7/16 is the height of the seat i believe. maybe try getting a 3/8" seat and see if its any better since you don't have the original. If you know the brand of the faucet, you might be able to find the oem seats, most brands only used one or two sizes
the_man is offline   Reply With Quote
Old 10-25-2010, 07:03 AM   #5
Newbie
 
Join Date: Oct 2010
Posts: 7
Default

Pressure drop after replacing faucet seat


By "height of the seat" do you mean the diameter of the opening?

Thanks.
plumbing_noob is offline   Reply With Quote
Old 10-25-2010, 09:14 AM   #6
Member
 
Join Date: Aug 2010
Posts: 601
Default

Pressure drop after replacing faucet seat


when i wrote that I didn't, but as i think about it i believe thats what it refers to. i seem to remember looking at seats that were identical in measurements and looked completely different. One thing you can do... take the stem with you next time you go to HD/Lowes. They have a book to match parts for valves. Match the stem, it'll tell you the seat that you need to put in

the_man is offline   Reply With Quote
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
Questions about water pressure regulation.. MrSimmonsSr Plumbing 20 11-30-2012 09:43 PM
NO hot water pressure in just 1 faucet es0412 Plumbing 4 01-17-2010 05:34 PM
Low water pressure on Kitchen faucet DIY_user Plumbing 3 01-08-2010 12:08 PM
Pot lights in a drop ceiling Howdy Electrical 3 03-14-2008 08:23 PM
pressure drop grgree Plumbing 7 11-06-2007 10:57 PM




Top of Page | View New Posts

Copyright © 2003-2014 Escalate Media. All Rights Reserved.