Need to support 15th of ABS pipe
hello - I have a washer/dryer combo in my kitchen. I drilled a hole through my kitchen tile and I am running the washer waste pipe from the washer through the kitchen floor and into an ABS pipe.
I have a piece of ABS pipe that is 15feet long. One end of the pipe is 'T'ed in to the main waste pipe in my basement (the T is 4 foot of the ground), on the other end of the 15 foot pipe (which is running horizontal across the basement floor that is 4 foot of the basement floor) I have attached an elbow that will have a pipe extending from it, and where the washer waste pipe enters into. How do I support this 15foot pipe, that runs from the main waste pipe in the basement to where I have attached the elbow? And is there a standard where I need to support this pipe evey 4 foot or something like that???? Does that kinda make sense - lol, any help would be appreciated. |
|
|
|
|
|
#2 |
|
Newbie
Join Date: Aug 2006
Posts: 5
|
Need to support 15th of ABS pipe
I'm not a plumber, but Is the pipe running against a wall? If so, I would imagine you could just use plastic pipe strapping or plastic clips attached to the wall to support it. As far as how often to apply support, I really don't know. Don't you also need to pitch the pipe 1/4" / foot towards the main stack? If so, then the end with your elbow should be at least 4 foot 3.75 inches from the floor. I'd also imagine you would need a p-trap instead of that elbow. Also, being that far away, won't you need separate venting for that p-trap?
Again, I'm not a plumber, so all this info may be wrong, but this info is what I've gathered from reading various plumbing books and how-tos. |
|
|
|
|
|
#3 |
|
Journeyman Plumber
Join Date: Jun 2006
Location: Eugene, Oregon
Posts: 1,994
|
Need to support 15th of ABS pipe
According to UPC Code support every 4'
|
|
|
|
|
|
#4 |
|
Newbie
Join Date: Aug 2006
Posts: 3
|
Need to support 15th of ABS pipe
Thanks for the info, yea I said elbow just to make my description a little easier to understand. I have a P-trap (where I said the elbow was), and I also have a cheater valve in the middle of the 15foot pipe. I the pipe is approximately 2 inches from the wall. What I have decide to do is to make a wooded support and when I am putting my studs up I will then anchor the pipe to the stud wall frame. Thanks for the help!!!! Yea 4foot looks and sounds right - thanks
|
|
|
|
![]() |
| Thread Tools | Search this Thread |
| Display Modes | |
|
|
Similar Threads
|
||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| Basement Rough In Advice Needed | mikemille | Plumbing | 5 | 02-18-2007 10:55 AM |
| Use of coupling fitting on gas pipe | Fred | Plumbing | 3 | 01-28-2007 07:13 AM |
| Replacement pipe for hot water heat? | Tmb9862 | HVAC | 18 | 01-12-2007 04:31 PM |
| Need help with basement support | jaw522 | Building & Construction | 3 | 10-25-2006 09:55 AM |
| Vent Pipe Leak | romeguy1 | Plumbing | 9 | 12-11-2005 01:08 AM |