My closet flange is too high?


I am taking up my tile floor in the bathroom and I'm going to retile. The tile floor in the bathroom is considerably higher than the hall floor and I found that not only has tile been tiled over tile Which was tiled over tile, but the mortar bed below is really thick. The problem is, my closet flange sits a full 1 3/4" off my plywood subfloor. I was going to use 1/4" hardie and a 1/4" tile. The Flange is cast iron... the flange is going to be too high for me, right? I mean, even I bump up to 1/2" backer it will still be too high, right? What is the highest the flange can sit atop of the finished floor?

Advertisement


Last edited by J187; 04-18-2009 at 09:01 PM.
J187 is offline   Reply With Quote
Old 04-18-2009, 09:25 PM   #2
Member
 
Join Date: Sep 2006
Posts: 1,670
Rewards Points: 1,000
Default

My closet flange is too high?


Bottom line is that it has to sit "on" the flooring. It should also be attached to the floor with screws. Hopefully, you have access to the area under the floor and can cut the cast iron pipe and lower the flange to fit your new tile height.

Advertisement

__________________
If you have never made a mistake, you haven't done much.
majakdragon is offline   Reply With Quote
Old 04-18-2009, 10:05 PM   #3
Member
 
Join Date: Apr 2009
Posts: 203
Rewards Points: 150
Default

My closet flange is too high?


The bottom of the flange should be sitting on the finish floor.
the only way to fix that is to take the flange out and lower it. My suggestion find an older plumber use to working with cast iron and have him fix it. he would probably be over 50 to have enough of experince to work on cast iron. I am 55 and they were phasing out cast iron when I came into the trade in the 70's. Although it is still used on some commercial jobs for noise reasons. It is much quieter than pvc.
al's sewer is offline   Reply With Quote
Old 04-18-2009, 10:51 PM   #4
They're all fixer-uppers
 
J187's Avatar
 
Join Date: May 2006
Location: MA
Posts: 991
Rewards Points: 500
Default

My closet flange is too high?


I cannot afford a plumber right now. Guess I'll be raising tfe floor.

Last edited by J187; 04-19-2009 at 09:42 AM.
J187 is offline   Reply With Quote
Old 04-19-2009, 09:43 AM   #5
They're all fixer-uppers
 
J187's Avatar
 
Join Date: May 2006
Location: MA
Posts: 991
Rewards Points: 500
Default

My closet flange is too high?


Is this my only option?
J187 is offline   Reply With Quote
Old 04-19-2009, 10:05 AM   #6
Member
 
Join Date: Dec 2008
Posts: 42
Rewards Points: 25
Default

My closet flange is too high?


I am in the trade in new york .and 42 all we use is cast ..
metx is offline   Reply With Quote
Old 04-19-2009, 10:09 AM   #7
General Contractor
 
HWConstruction's Avatar
 
Join Date: Jan 2009
Location: Indiana
Posts: 50
Rewards Points: 25
Default

My closet flange is too high?


Is the bath on a slab, crawl or basement? Can you get to the cast pipe?
HWConstruction is offline   Reply With Quote
Old 04-19-2009, 10:13 AM   #8
Member
 
Join Date: Sep 2006
Posts: 1,670
Rewards Points: 1,000
Default

My closet flange is too high?


It is not your your only option if you have access under the house. You could cut the cast iron and put a No-hub or Fernco coupling and switch to PVC. This way you could lower the flange to the proper height.
__________________
If you have never made a mistake, you haven't done much.
majakdragon is offline   Reply With Quote
Old 04-19-2009, 10:44 AM   #9
Member
 
Join Date: Apr 2009
Posts: 203
Rewards Points: 150
Default

My closet flange is too high?


no its not your only option.As stated above if the pipe is accessable from underneath you can try doing it yourself by cutting out the cast iron and replacing with pvc Using either a fernco or no hub band. If you decide to do this I would recommend using a transition no hub band to go from 4 inch pvc to 4 inch cast iron. The reason for this is the pvc is slightly thicker than the cast and it makes the transition look and work better as the thickness difference is corrected in the no hub band. This is of course you are working with 4 inch pipe which most likely you are. The transition no hubs are available in other pipe sizes also.
al's sewer is offline   Reply With Quote
Old 04-19-2009, 11:06 AM   #10
They're all fixer-uppers
 
J187's Avatar
 
Join Date: May 2006
Location: MA
Posts: 991
Rewards Points: 500
Default

My closet flange is too high?


Split level home I have access. Now I have to make a decision.., thanks guys!
J187 is offline   Reply With Quote
Old 04-19-2009, 11:10 AM   #11
Member
 
Join Date: Apr 2009
Posts: 203
Rewards Points: 150
Default

My closet flange is too high?


Quote:
Originally Posted by metx View Post
I am in the trade in new york .and 42 all we use is cast ..
Yes I know it is still used in commercial building alot for noise and fire regulations I was simply reffering to residential plumbing. although it might still be being used in some areas for residential.
al's sewer is offline   Reply With Quote
Old 04-19-2009, 11:13 AM   #12
Member
 
Join Date: Sep 2006
Posts: 1,670
Rewards Points: 1,000
Default

My closet flange is too high?


Depending on the age of your home, the cast iron may be connected with No-hub couplings. I did a lot of jobs like that in the early 70's. You would still need to get a cast iron to PVC coupling. If the cast iron is hub type, with poured lead joints, it is a bit more work.
__________________
If you have never made a mistake, you haven't done much.
majakdragon is offline   Reply With Quote
Old 04-19-2009, 03:08 PM   #13
Member
 
Join Date: Dec 2006
Location: Canonsburg, PA (Pittsburgh)
Posts: 442
Rewards Points: 264
Default

My closet flange is too high?


Can you post a picture from under the floor and one from above? This may not be as complected as you think.
RegeSullivan is offline   Reply With Quote
Old 04-20-2009, 07:30 AM   #14
Member
 
Join Date: Jan 2009
Location: Long Island
Posts: 348
Rewards Points: 250
Default

My closet flange is too high?


<~~ not a fan of hardy boards in bathrooms. Consider putting down a mud floor of portland and sand.( 5 parts sand, 1 part cement) You can perfectly level the floor and and its a much better base for tile and you can raise your floor that way.
II Weeks is offline   Reply With Quote
Old 04-20-2009, 08:42 AM   #15
Member
 
Join Date: Dec 2008
Posts: 42
Rewards Points: 25
Default

My closet flange is too high?


first make sure what it is .lead or cast .if cast it is connected with a nohub or frenco .if lead it is sweated on the ferell .

Advertisement

metx is offline   Reply With Quote
Reply


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
What to do with Closet flange jenoble99 Plumbing 1 01-05-2009 02:56 AM
Closet flange: flush with finished floor, on on top of? rjhaleymd Plumbing 4 11-20-2008 07:43 PM
Toilet closet flange kensington Plumbing 5 04-27-2008 09:19 AM
Closet flange unsupported Richo Plumbing 6 01-02-2008 03:44 PM
closet flange wax ring problem elkmo Plumbing 2 01-14-2006 03:30 PM




Top of Page | View New Posts