Lockeset 09-22-2010 05:43 PM

How to tie a new vent into an existing?
 
Here's the deal, I am upgrading my tub to a stall shower so I need to upgrade the plumbing from the current 1 1/2" to 2". The existing drain goes horizontally over to the toilet stack, but I am not opening that wall up so I would like to cap that off and run a new drain down to the basement. I would also run a new 2" vent pipe up into the attic where there is an existing 2" vent pipe running horizontally.

I planned on cutting a sanitary Tee into that existing horizontal vent pipe and running the new vent into that.

Will that be OK?

If so, which way I should I face the sanitary Tee? So that the fumes can go up smoothly or so that the rain water can flow down smoothly?

TheEplumber 09-22-2010 07:34 PM

You can pipe it as you described. you can also vent a shower with 1.5"
When placing vent fittings, think like water. You want to drain back to the drainline.