Flapper valve infrequently doesn't completely close


It's the hinged kind with a tube at 45 degrees that fills up.
http://www.google.com/imgres?imgurl=...w=1374&bih=812
It hangs open about 1/8". What should I check for first? Hinge burrs?

It might happen once/month but we don't use that bathroom very often.

Advertisement


Last edited by Yoyizit; 08-29-2010 at 09:01 PM.
Yoyizit is offline   Reply With Quote
Old 08-30-2010, 09:45 AM   #2
Household Handyman
 
Join Date: Feb 2009
Location: Albany, Ga.
Posts: 2,294
Rewards Points: 1,040
Default

Flapper valve infrequently doesn't completely close


I, just me maybe, particularly don't like those flappers with the float thingy's made onto them. I change a lot of the flapper units out because of the small leaks. I always try to use a really good unit, bought at plumbing supply house, not big box stores. One trick I was taught, and still use, is to use fine steel wool to sort of "polish" the seat the flapper seals to. It seems that sometimes there may be some coating on there which I cannot see nor feel, but the steel wool works. Just a light cleaning with the steel wool, then wipe good with a clean cloth. Inspect the seat really good, I have seen them with tiny chips in them. They are easily replaced. David

Advertisement

Thurman is offline   Reply With Quote
Old 08-30-2010, 03:10 PM   #3
Member
 
Join Date: May 2008
Location: north east
Posts: 728
Rewards Points: 500
Default

Flapper valve infrequently doesn't completely close


I also have problems with those type flappers,, I'd just go ahead and replace it, you probably already hang around waiting for it to fill and shut off.
__________________
LIVING THE DREAM
DUDE! is offline   Reply With Quote
Old 08-30-2010, 03:25 PM   #4
Member
 
Join Date: Jul 2010
Location: Ontario Canada, Toronto to be exact.
Posts: 1,373
Rewards Points: 500
Default

Flapper valve infrequently doesn't completely close


Well my best advice is to replace the flapper. Take it off your unit and bring it with you to the hardware/plumbing store and see if you can get the same one. But shut your supply line off before you remove the flapper.
epson is offline   Reply With Quote
Old 08-30-2010, 04:54 PM   #5
Member
 
Join Date: Jul 2008
Location: NW of D.C.
Posts: 5,990
Rewards Points: 2,000
Default

Flapper valve infrequently doesn't completely close


Thanks for your replies.

I tried something else first: turned off the water and flushed it.
When I took the lid off, the flapper was standing open so I lengthened the pull chain a few notches. Too long a chain will probably start giving me incomplete flushes, but I'm not there yet.

It'll probably be a month before I can say with some certainty that this worked. I'll make it a point to use this bathroom more often until this is solved.
Yoyizit is offline   Reply With Quote
Reply


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
How to diagnose gas valve problems Nestor_Kelebay How To Guides 28 10-30-2013 05:19 PM
Resource for understanding gas valve? darsunt HVAC 19 02-04-2009 12:08 AM
Leaking pressure relief valve Chris Magee Plumbing 12 08-12-2008 08:48 PM
Toilet: water still coming from BOTTOM of Inlet Valve DIY Mom Plumbing 1 08-12-2008 01:43 PM
Best 1/2 inch water shut off valve. Nestor_Kelebay Plumbing 10 07-25-2008 12:16 PM




Top of Page | View New Posts