Failed inspection


Well I had some plumbing work done in my kitchen and had the inspector come out and check it for me today. He failed me for the vent pipe from the sink being to close to an upstairs window (apparently it needs to be 10 feet away and it's only about 8 feet away. My question is this: This isn't a new install I just had a plumber change the angle of the pipe so I wouldn't need a sofet in my kitchen. The inspector told my wife to have it moved where the bathroom vent is (about 5 feet away in the roof). I have the plumber coming out tomorrow to see what he can do, but I don't see anyway around this. Do you think I can question about a grandfather clause or something like that due to the fact that the pipe had already been there since I bought the house? I don't want to question the inspector and tick him off, but if I can get around this without moving the pipe I would love to. If I have to move it that means patching the hole in the roof along with the cost of the plumber moving the pipe.

Any ideas what I can do to possibly get around this?

Thanks.

Advertisement

pjm is offline   Reply With Quote
Old 05-06-2008, 07:51 PM   #2
Member
 
Join Date: May 2008
Location: north east
Posts: 728
Rewards Points: 500
Default

Failed inspection


easy for me to say, its not my inspection, but truth be told, the inspector is only looking out for your safety, and anyone whom may own your house in the future, good luck.

Advertisement

DUDE! is offline   Reply With Quote
Old 05-06-2008, 07:52 PM   #3
Journeyman Plumber
 
Ron The Plumber's Avatar
 
Join Date: Jun 2006
Location: Eugene, Oregon
Posts: 1,994
Rewards Points: 1,000
Default

Failed inspection


You can't dispute the code, fix it and be done with it.
__________________
Fix it right the first time, so you won't have to fix it a 2nd time.

2008 Oregon Specialty Plumbing Codes
Ron The Plumber is offline   Reply With Quote
Old 05-06-2008, 09:42 PM   #4
pjm
Member
 
Join Date: Apr 2008
Posts: 110
Rewards Points: 75
Default

Failed inspection


That's what I thought. I just didn't know if anyone knew of any grandfather clause it might fall under, but I guess the inspector would know about that. Looks like I need a roofer now too.
pjm is offline   Reply With Quote
Old 05-06-2008, 10:12 PM   #5
Registered User
 
Termite's Avatar
 
Join Date: Apr 2008
Posts: 6,520
Rewards Points: 2,000
Default

Failed inspection


As an inspector, my opinion of that call is that it is...Shall we say chicken poop. There's no life safety hazard about it. Odor is the big issue.
But, it is code.

If your plumber did not just install the vent, I would contact the inspector and try to discuss it with him. You're not necessarily grandfathered, but they should be willing to make an exception over two feet on an existing pipe. It seems unreasonable to make you change an existing condition unless there is an identifiable life safety hazard.
Termite is offline   Reply With Quote
Old 05-06-2008, 11:10 PM   #6
Underground Techie
 
sevver's Avatar
 
Join Date: Apr 2008
Location: Chicago land
Posts: 96
Rewards Points: 75
Default

Failed inspection


The thing is, what you are dealing with is potentially methane gas. So it could be life or death, odorless, colorless, tasteless, that is what it is, and I am not really sure if it is the fact that it is too close to the window in the wall, as it is within ten feet of a window where it leaves the roof. Is that what it is? Could you just toss a 45 on it outside the roof and stick a piece of pipe in there? It would look sort of funny, but it would solve a problem. Or, what if you extended it further in the air?
sevver is offline   Reply With Quote
Old 05-07-2008, 07:06 AM   #7
pjm
Member
 
Join Date: Apr 2008
Posts: 110
Rewards Points: 75
Default

Failed inspection


I'm having the plumber come over this morning and take a look. I think I have to call the inspector and see just what the problem is and how I can go about fixing it. I've seen other vent pipes extend much higher than mine they look kind of wierd, but if it saves me a roofing bill I could live with it.

I'll let you know what develops.
pjm is offline   Reply With Quote
Old 05-07-2008, 09:54 AM   #8
pjm
Member
 
Join Date: Apr 2008
Posts: 110
Rewards Points: 75
Default

Failed inspection


Well the plumber came by this morning and said we need to move the pipe. He said that once you work on existing plumbing it needs to meet the new codes so I have no recourse. He will move it for me later today or sometime this week. Now I just need to patch the hole in my roof. guess i'm off to the roofing forum now !
pjm is offline   Reply With Quote
Old 05-09-2008, 03:30 AM   #9
Member
 
Lansing's Avatar
 
Join Date: May 2008
Location: Nova Scotia, Canada
Posts: 52
Rewards Points: 75
Default

Failed inspection


My uncle was a master plumber and I worked as his helper on jobs he did for my father , a general contractor...It's right to move the vent pipe...

I have seen it taken up to the attic and a line run to where it was safe to go through the roof so you did not see a odd pipe set outside...My question is why did your plumber not to it right the first time...He should have known the code and that it was going to be inspected ???

Lansing
Lansing is offline   Reply With Quote
Old 05-09-2008, 05:09 PM   #10
Member
 
Join Date: Jul 2007
Posts: 1,719
Rewards Points: 1,258
Default

Failed inspection


Quote:
Originally Posted by sevver View Post
The thing is, what you are dealing with is potentially methane gas. So it could be life or death,
Yep, countless people have died because their sink vent pipe was only 8 feet from their window instead of 10.

It's just a smell thing but you gotta do what you gotta do to pass the inspection.

Advertisement

jogr is online now   Reply With Quote
Reply


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
State Vehicle Inspection - ARGGH Leah Frances Off Topic 14 04-05-2008 01:59 PM
preparing for inspection brackh Electrical 18 03-18-2008 09:45 PM
Failed framing inspection Hope I can sleep tonight!! NJlumberjack Building & Construction 14 01-16-2008 08:50 PM
Need Advice for Final Inspection Bobby General DIY Discussions 5 09-22-2006 03:50 PM
How is electrical inspector doing the inspection... KUIPORNG Electrical 2 08-15-2006 09:46 PM




Top of Page | View New Posts