DIY Chatroom -  DIY Home Improvement Forum
    DIY Forum     DIY Blogs     Photos     Woodworking     Extreme How To     Advertise     Contact Us  
Go Back   DIY Chatroom - DIY Home Improvement Forum > Home Improvement > Plumbing


CLICK HERE AND JOIN OUR COMMUNITY TODAY...IT'S FREE!
Reply
 
Thread Tools Search this Thread Display Modes
Old 06-01-2009, 06:35 PM   #1
Member
 
Join Date: Mar 2009
Location: South Caroling
Posts: 38
Default Copper

My house is 30 or 40 years old and I have found 3 pin hole leaks, I guess is how I would put it. One seemed like a fix under the kitchen sink and was almost like a T connection that fed to a hose just laying in the crawl. The second hole also seemed to be a T connection feeding a line that I guess was for an Ice maker line for my fridge. I can come up for reasons why those two exist. Now the third, I discovered yesterday while I was checking on my previous patch. Another pin hole on the hot water line coming from the HWH, I can't figure out how that happened, MY question is whether or not these pin holes just happen or not, and if I am better off getting some copper to pex fittings and switch out all that I can. thanks.

Toolmaster is offline   Reply With Quote
Join DIYChatroom.com

Join the #1 DIY Forum Today - It's Totally Free!

DIYChatroom.com - Are you about to start a new home improvement task and need some help? Do you need advise on what products to buy? Or maybe you can give others some advice? No matter where you fit in you'll find that DIY Chatroom is a great community to join. Best of all it's totally free.

Join DIYChatroom.com - Click Here
JOIN FOR FREE


Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. DIYChatroom.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any home improvement task!
Old 06-01-2009, 09:45 PM   #2
Member
 
Join Date: Mar 2009
Posts: 453
Default

Two causes of pin holes that I know of are excess flux when sweating and the other is cause by not reaming out the tubes after cutting. The flux is an acid and if a bubble of it settles and cools in a spot it will eventually eat through the copper. The other is because the burrs on the inside of the tube cause a vortex action immediately after the burr which wears away the copper.
hayewe farm is offline   Reply With Quote
Old 06-01-2009, 10:01 PM   #3
Member
 
Join Date: Mar 2009
Location: South Caroling
Posts: 38
Default

OK, when I did my patches I used a tubing cutter, now would that cause more problems down the road because I know that I didn't ream out the tubes at all, I thought I was doing a sufficient job. What should I use to do that in future patches or repairs? and How would I keep the burrs from entering the line? Now the excess flux settling and causing a bubble how long does that take to eat through the pipe, b/c no one has been under there to touch anything in at least 5 years.
Toolmaster is offline   Reply With Quote
Old 06-01-2009, 11:52 PM   #4
Member
 
Join Date: Mar 2009
Posts: 453
Default

If you used a tube cutter similar to this if you notice there is a fold out blade on the back. It is used to ream out the tube after cutting. The cutter rolls the inside edge of the tubbing and that is what causes the problem.
hayewe farm is offline   Reply With Quote
Old 06-02-2009, 12:04 AM   #5
Oldie but Newbie
 
Join Date: Apr 2009
Location: Sierra Foothills
Posts: 85
Default

Another possibility to consider is that your water may be acidic. If so, the water could be literally leaching the copper out of the pipes.

Do you have blue-green stains in any of your sinks or toilets? If so, those are copper deposits.

If this is the case, and you are beginning to develop leaks, you may be faced with replacing all of your copper pipes. To prevent further leaching, you would need to install a water treatment system to filter your water through limestone sand.
LookoutRanch is offline   Reply With Quote
Old 06-02-2009, 02:33 AM   #6
DIY'r
 
ScottR's Avatar
 
Join Date: Oct 2008
Location: Hicksville, NY (Yes, it's an actual town).
Posts: 497
Default

Three leaks in a short period of time on old (or old-ish) work would scare me, unless you think that maybe the leaks at the tee fittings were caused by poor DIY repairs.. (Not blaming you here; from the last guy). Initially it sounded like that to me based upon your hose-to-nowhere comment.

Quote:
Another pin hole on the hot water line coming from the HWH,
That one is more worrisome if you're saying the pin hole was in the pipe, away from any fittings.

In your shoes, I'd cut out a couple of short (6") pieces of easy-to-access pipe from different spots around the crawl space and see what the inside looks like. (Obviously patching some copper back in so you can use your water ). If you have pitting or extensive corrosion on the inner walls in all the samples then LookoutRanch may be right and you need a complete re-fit.

On the other hand, if all the samples look reasonably good (a little oxidation on 30-40 y/o copper is OK), then it might have just been some bad fittings and the mid-pipe leak could be a coincidence -- mfr. defect or something.
ScottR is offline   Reply With Quote
Old 06-02-2009, 02:38 AM   #7
Civil Engineer
 
Join Date: Mar 2009
Location: Boston
Posts: 392
Default

My house was built in 1959, and used 50/50 tin lead solder on all the joints. I am on well water, pH about 5 to 5.5 (relatively acidic). Over time, all of the copper pipes developed pinholes, especially at the joints. I ended up replacing all of the pipes with PEX, since I did not want to install a water treatment system to change the pH to neutral.
Daniel Holzman is offline   Reply With Quote
Old 06-02-2009, 10:06 PM   #8
Member
 
Join Date: Mar 2009
Location: South Caroling
Posts: 38
Default

thanks for the advice and knowledge, the first pin hole was a patch or at least looked like one under the sink, nothing was leaking that I noticed, and that was a year ago. The 2nd seemed to be an old connection that rusted, The 3rd is what scares me. I will definitly take all advice, I have to do something , Im trying to move out of here in a year or two.
Toolmaster is offline   Reply With Quote
Old 06-02-2009, 10:20 PM   #9
DIY'r
 
ScottR's Avatar
 
Join Date: Oct 2008
Location: Hicksville, NY (Yes, it's an actual town).
Posts: 497
Default

If you're moving out in a year or 2 then patch patch patch and let the next guy worry about it.. (And hope he doesn't have a thorough home inspector.. )
ScottR is offline   Reply With Quote
Old 06-03-2009, 01:45 AM   #10
Member
 
Join Date: May 2009
Posts: 41
Default

i was working on my plumbing today replaciing a few leaky shutoff valves, i noticed that the solder joints 40 years old were not very tight at all , i was able to pull solder joints apart withg my hands. after i was done one of the old joints blew apart after i turned the water back on. I think its just old plumbing that weakens or something. i dont get it though cause the joints are water proof.
oldrivers is offline   Reply With Quote
Reply


More On This Topic

I’m Lee. I have a degree in architecture and about ten years construction experience, and today we are replacing the hot water pipe and valve. Now we’ve already installed the valve, which is a two outlet valve- one for the sink and one for... Read More »

I’m Lee. I have a degree in architecture and about ten years construction experience, and we’re installing a new dishwasher. The water inlet, which is, everything’s located on the bottom. You just want to take some Teflon tape and... Read More »

How to Dry Fit Copper Pipes
How to Dry Fit Copper Pipes by Expert Village

Hey everybody Don Golden here with Expert Village. We are talking about copper piping and copper fitting. We have prepped these two little demo pieces and the 90 degree union that I am going to show you how to sweat shortly but I got a little ahead of... Read More »

How to Check for Car Leaks
How to Check for Car Leaks by Expert Village

Hi this is Jeff Wong with Expert Village and today we're going to learn the basics of maintaining your vehicle. In this segment we're going to examine how to tell if your car might be leaking a fluid and what that fluid might be. So with this older... Read More »

Hey everybody Don Golden for Expert Village and we are having fun with copper today, copper piping. We just put this joint together and I felt it was my duty to show you a new technology that really makes this even easier and it is pretty easy as it is... Read More »

Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
Relocating Cold & Hot Copper Pipes for washer atm Plumbing 0 03-26-2009 10:52 AM
Flexible copper or Rigid Copper for solar? Piedmont HVAC 5 06-11-2008 11:47 PM
Flexible Copper or Rigid Copper? Piedmont Plumbing 1 06-10-2008 03:40 PM
copper strap around copper pipe? analogmusicman Plumbing 3 06-04-2008 12:55 PM
brass trap to copper drain? bluebee1314 Plumbing 3 04-03-2007 12:29 AM

Top of Page | View New Posts


All times are GMT -4. The time now is 11:00 AM.


Powered by vBulletin® Version 3.8.1
Copyright ©2000 - 2009, Jelsoft Enterprises Ltd.
© 2003 - 2009 The Building Network LLC