Cold and Hot Water Issue


I have been in a new construction home for about 5 years. The cold water was always ice cold and hot was hot. Within the past few months, we noticed that sometimes hot water comes out of the cold water faucets. This is for all faucets. This never happened before and we are not aware of anything changing. We have WeilMcClain furnaces and one is hooked up to a hot water holding tank which heats the water. I do notice that the cold water feed pipe gets warm and/or hot up it. Can anyone provide any insight to our problem and possible ways to fix it? Also, why would it work for a number of years and then go weird. I believe I should call a plumber but wanted to be knowledgeable before I did so.

Thanks.

westendmedia is offline   Reply With Quote
Join DIYChatroom.com

Join the #1 DIY Forum Today - It's Totally Free!

DIYChatroom.com - Are you about to start a new home improvement task and need some help? Do you need advise on what products to buy? Or maybe you can give others some advice? No matter where you fit in you'll find that DIY Chatroom is a great community to join. Best of all it's totally free.

Join DIYChatroom.com - Click Here
JOIN FOR FREE


Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. DIYChatroom.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any home improvement task!
Old 12-28-2009, 09:08 PM   #2
Household Handyman
 
Join Date: Feb 2009
Location: Albany, Ga.
Posts: 2,210
Default

Cold and Hot Water Issue


I hope this can be of some help: Recently (Sept-Oct) I was visiting my daughter in Fairbanks, AK. She had lived in a two apartment unit which has a fuel-oil fired boiler which provides the hot water to heat water in the "water heating tank". Make sense? There's a heat exchanger in the "water heating tank". This boiler was replaced the fall of '08 and worked just fine until Sept. '09. The same problem occurred with hot water coming from the cold water piping. I was there when the boiler tech came to look at it, and yes, the cold water inlet pipe would get quite hot going back away from the unit. He says "it should not do that", TA-DAH! Good deduction there! His explanation was much like what happens with gas or electric fired units--the water expands when it gets hot and backs up into the cold water feed line which let it into the cold water piping. Or so he said. He put in a check valve (first time I saw a ProPress used, quite neat) and the problem was solved. Any chance this may help with yours? Thanks, David

Thurman is offline   Reply With Quote
Old 12-29-2009, 07:22 AM   #3
Newbie
 
Join Date: Dec 2009
Posts: 4
Default

Cold and Hot Water Issue


Thurman, Yes it does make sense and that was a solution I was leaning toward. It has been bothering me as to the why part of it and I think you shed the light there. I want to be knowledgeable when a plumber comes in so I don't get ripped off. Thanks!
westendmedia is offline   Reply With Quote
Old 12-29-2009, 08:03 AM   #4
Member
 
Join Date: Nov 2007
Location: Nashua, NH, USA
Posts: 6,729
Default

Cold and Hot Water Issue


Do you turn off the shower or bathtub at the showerhead or sprayer instead of using the faucets? This could cause hot water to go down the cold pipe or vice versa.

This could also result in a flood if the sprayer hose burst with nobodyh around but that is another program.
__________________
The disadvantages of crab apple trees. In summer, the apples are too sour to pick and eat. In winter the birds come and leave dropping all over the place.

Last edited by AllanJ; 12-29-2009 at 08:07 AM.
AllanJ is offline   Reply With Quote
Old 12-29-2009, 09:41 AM   #5
gravity always wins
 
Join Date: Feb 2008
Location: Central Pennsylvania
Posts: 2,374
Default

Cold and Hot Water Issue


Also check your washing machine connections. Make sure there isn't a solenoid valve hung open in the washer that's creating a cross connection.
Maintenance 6 is offline   Reply With Quote
Reply

Tags
faucet, furnace, heater, hot water, water


-->
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Top of Page | View New Posts


All times are GMT -4. The time now is 09:04 PM.


© 2003 - 2010 The Building Network LLC