AO Smith water heater burner wont stay lit.


It is a AO Smith promax GCV 40 100 water heater to be exact. I can get the pilot to light may take a second or two to keep it light but when I turn it to the on position and turn up the temperature the burner lights. It goes out along with the pilot light after a minute or two of heating. I do hear a slight "click" when it goes out. I have tried cleaning it to make sure its not starved for oxygen, didn't help. I checked to see if its under warranty and it is not. PLEASE HELP!

Fortypopper is offline   Reply With Quote
Old 04-08-2012, 07:45 PM   #2
DIY staff
 
Join Date: Sep 2009
Location: Kane county,Illinois
Posts: 21,137
Default

AO Smith water heater burner wont stay lit.


Is that a sealed unit (no door to the burners--clicker to light--little glass window)

or an open unit--(removable door light with a match)?

__________________
New members: Adding your location to your profile helps in many ways.--M--
oh'mike is offline   Reply With Quote
Old 04-08-2012, 07:48 PM   #3
Newbie
 
Join Date: Apr 2012
Location: Colorado Springs, CO
Posts: 6
Default

AO Smith water heater burner wont stay lit.


Quote:
Originally Posted by oh'mike View Post
Is that a sealed unit (no door to the burners--clicker to light--little glass window)

or an open unit--(removable door light with a match)?
Yes, it is sealed. Glass window with clicker to light.
Fortypopper is offline   Reply With Quote
Old 04-08-2012, 08:37 PM   #4
DIY staff
 
Join Date: Sep 2009
Location: Kane county,Illinois
Posts: 21,137
Default

AO Smith water heater burner wont stay lit.


Call a plumbing supply house --you may not be able to buy the parts you need--usually only sold to licenced plumbers---either the thermo couple is dead or the flame sensor is defective---often the whole burner unit must be replaced---sorry---
__________________
New members: Adding your location to your profile helps in many ways.--M--
oh'mike is offline   Reply With Quote
Old 04-08-2012, 08:40 PM   #5
DIY staff
 
Join Date: Sep 2009
Location: Kane county,Illinois
Posts: 21,137
Default

AO Smith water heater burner wont stay lit.


AO smith has a technical help site and phone number---google that--my bookmarks aren't working tonight--
__________________
New members: Adding your location to your profile helps in many ways.--M--
oh'mike is offline   Reply With Quote
Old 04-08-2012, 08:41 PM   #6
Newbie
 
Join Date: Apr 2012
Location: Colorado Springs, CO
Posts: 6
Default

AO Smith water heater burner wont stay lit.


Ok, thanks for replying I've posted a video to show what is actually happening.

http://www.youtube.com/watch?v=8eIww...p5LWQJopDsmOoQ
Fortypopper is offline   Reply With Quote
Old 04-08-2012, 08:54 PM   #7
DIY staff
 
Join Date: Sep 2009
Location: Kane county,Illinois
Posts: 21,137
Default

AO Smith water heater burner wont stay lit.


Sorry--computer is wacky tonight---no videos for me---Mike---
__________________
New members: Adding your location to your profile helps in many ways.--M--
oh'mike is offline   Reply With Quote
Old 04-08-2012, 09:00 PM   #8
DIY staff
 
Join Date: Sep 2009
Location: Kane county,Illinois
Posts: 21,137
Default

AO Smith water heater burner wont stay lit.


Come bail me out! One of the plumbesr here will jump in soon--I see Alan is on --there are some truely good plumbers here--one of them will be along soon---
__________________
New members: Adding your location to your profile helps in many ways.--M--
oh'mike is offline   Reply With Quote
Old 04-08-2012, 09:05 PM   #9
Newbie
 
Join Date: Apr 2012
Location: Colorado Springs, CO
Posts: 6
Default

AO Smith water heater burner wont stay lit.


Thank you!
Fortypopper is offline   Reply With Quote
Old 04-08-2012, 09:39 PM   #10
Member
 
Join Date: Oct 2011
Location: pa
Posts: 4,244
Default

AO Smith water heater burner wont stay lit.


seems like a weak thermocupler ..did not see in the video if there is a tempeture sensor for cloged vent....the thermocuppling could be changed...could pick up at local hardware...

Last edited by ben's plumbing; 04-08-2012 at 09:59 PM.
ben's plumbing is offline   Reply With Quote
Old 04-08-2012, 09:47 PM   #11
DIY staff
 
Join Date: Sep 2009
Location: Kane county,Illinois
Posts: 21,137
Default

AO Smith water heater burner wont stay lit.


Ben--I don't know about A.O. Smith--but most of the sealed units I have delt with can not use a universal thermo couple---Must be original equipment---different threads---
__________________
New members: Adding your location to your profile helps in many ways.--M--
oh'mike is offline   Reply With Quote
Old 04-08-2012, 09:58 PM   #12
Member
 
Join Date: Oct 2011
Location: pa
Posts: 4,244
Default

AO Smith water heater burner wont stay lit.


Quote:
Originally Posted by oh'mike View Post
Ben--I don't know about A.O. Smith--but most of the sealed units I have delt with can not use a universal thermo couple---Must be original equipment---different threads---
most tanks we deal with use univerisal ..except whirpool they have reverse threads....thanks for the info like you don't see any ao smiths....maybe someone else will chime in???
ben's plumbing is offline   Reply With Quote
Old 04-08-2012, 10:04 PM   #13
DIY staff
 
Join Date: Sep 2009
Location: Kane county,Illinois
Posts: 21,137
Default

AO Smith water heater burner wont stay lit.


Good news on AO Smith--It was two Whirlpools that had me stopped---AO Smiths are better units and I have never needed to service one---
__________________
New members: Adding your location to your profile helps in many ways.--M--
oh'mike is offline   Reply With Quote
The Following User Says Thank You to oh'mike For This Useful Post:
ben's plumbing (04-08-2012)
Old 04-08-2012, 10:29 PM   #14
Newbie
 
Join Date: Apr 2012
Location: Colorado Springs, CO
Posts: 6
Default

AO Smith water heater burner wont stay lit.


Quote:
Originally Posted by oh'mike View Post
Ben--I don't know about A.O. Smith--but most of the sealed units I have delt with can not use a universal thermo couple---Must be original equipment---different threads---
Mike is right they cannot use universal thermo couples. Good news though I took out the whole assembly and scrubbed it down with a wire brush. Although it didn't look dirty...I re-installed it and its working fine now. Hope its not temporary. I thank you again for the time spent with me.
Fortypopper is offline   Reply With Quote
The Following 2 Users Say Thank You to Fortypopper For This Useful Post:
ben's plumbing (04-09-2012), oh'mike (04-11-2012)
Old 04-11-2012, 12:39 PM   #15
Newbie
 
Join Date: Apr 2012
Location: PA
Posts: 2
Question

AO Smith water heater burner wont stay lit.


Quote:
Originally Posted by Fortypopper View Post
Mike is right they cannot use universal thermo couples. Good news though I took out the whole assembly and scrubbed it down with a wire brush. Although it didn't look dirty...I re-installed it and its working fine now. Hope its not temporary. I thank you again for the time spent with me.

I'm still fighting with my water tank. Going to try to bleed it first. Easter filled my days. If need be, how would I go about taking out the whole assembly, like Fortypopper mentioned?

Gerrie is offline   Reply With Quote
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
AO Smith gas water heater - main burner won't stay lit ianshomeimp Appliances 3 05-31-2012 10:07 PM
No Hot water from A.O Smith GPSH/GPCR Gas Water Heater sghatty Plumbing 1 03-07-2012 07:23 PM
A.O. Smith water heater - cold water gma2rjc Plumbing 2 06-30-2011 10:16 AM
Pilot Light Won't Stay Lit on Water Heater jdolan HVAC 4 07-23-2010 04:42 PM
BradfordWhite Water Heater won't stay lit mwalla HVAC 3 03-02-2009 04:43 PM