DIY Chatroom -  DIY Home Improvement Forum
    DIY Forum     DIY Blogs     Photos     Woodworking     Advertise     Contact Us  

CLICK HERE AND JOIN OUR COMMUNITY TODAY...IT'S FREE!
Go Back   DIY Chatroom - DIY Home Improvement Forum > DIY Repair > General Discussion

Reply
 
Thread Tools Search this Thread Display Modes
Old 12-08-2007, 07:34 PM   #1
Newbie
 
Join Date: Dec 2007
Posts: 3
Question

Wall furnace blowing out


I have an old 30K+ BTU direct vent wall furnace that keeps going out. It will come on with the flame a nice strong blue color. Then, a moment later, all the flames turn orange and start to waver. This goes on for about 10 seconds then the flame goes out. Is this the valve not putting out enough gas or what? Gas flow to pilot is fine.

kwoodsong is offline   Reply With Quote
Join DIYChatroom.com

Join the #1 DIY Forum Today - It's Totally Free!

DIYChatroom.com - Are you about to start a new home improvement task and need some help? Do you need advise on what products to buy? Or maybe you can give others some advice? No matter where you fit in you'll find that DIY Chatroom is a great community to join. Best of all it's totally free.

Join DIYChatroom.com - Click Here
JOIN FOR FREE


Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. DIYChatroom.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any home improvement task!
Old 12-08-2007, 10:50 PM   #2
Newbie
 
Join Date: May 2007
Posts: 27
Default

Wall furnace blowing out


You can buy a meter for $80.00 - $160.00 to check the gas pressure. Or you can call a qualified tech which is your best bet. This isn't something a DIYer wants to mess with.

Buckeyetech is offline   Reply With Quote
Old 12-09-2007, 12:29 AM   #3
Newbie
 
Join Date: Dec 2007
Posts: 3
Default

Wall furnace blowing out


I know my gas pressure to the valve is fine as the other appliances run properly. I removed the burner and cleaned it thoroughly. There is about a 1" gap between the gas line coming from the valve to the entrance to the burner. Could too much air be getting sucked in there and disturbing the flow of gas?
kwoodsong is offline   Reply With Quote
Old 12-09-2007, 07:11 AM   #4
Newbie
 
Join Date: May 2007
Posts: 27
Default

Wall furnace blowing out


I doubt it very much. That's the way it was designed.
Buckeyetech is offline   Reply With Quote
Old 12-09-2007, 03:04 PM   #5
Member
 
Join Date: Nov 2005
Posts: 232
Default

Wall furnace blowing out


is this in pilot mode or burn mode??

Suspecting it is pilot mode and you 'may' have a bad or malfunctioning thermocoupler. That thermostat looking thing that is in the pilot flame to keep the pilot lit. IF it malfunctions it shuts off the gas supply to the pilot as a safety. Easy enough to replace and while its off blow out the pilot gas line to be sure dirt or spiders havent nested in there in the off season!!