#1 |
|
Member
Join Date: Feb 2010
Location: South Seattle
Posts: 507
|
Temporary support wall question
I am about to replace a 28 in. door in my house with a new, wider, 32 in. pre-hung door and install a new, properly sized header. The door separates the upstairs hallway from the unfinished attic space. The wall that the door is in supports both the hallway ceiling and the roof. The wall has a single top plate.
I was planning on building a simple support and putting it on the hallway side of the door but then realized that would do nothing to support the roof. So I thought about building a second support to put side on the attic side of the door, but that starts to feel like I'm over-doing it. Considering that the present header is a couple of 2x4s laying flat and that has been fine for the last 90 years, maybe I don't need a temporary support wall at all to do this work. Any thoughts? |
|
|
|
|
|
#2 |
|
Super Moderator
Join Date: Sep 2009
Location: Kane county,Illinois
Posts: 16,752
|
Temporary support wall question
A picture of the attic would sure help
You are only removing enough framing to widen the door?
__________________
New members: Adding your location to your profile helps in many ways.--M-- |
|
|
|
| The Following User Says Thank You to oh'mike For This Useful Post: | Gary in WA (02-01-2013) |
|
|
#3 |
|
Member
Join Date: Feb 2010
Location: South Seattle
Posts: 507
|
Temporary support wall question
I was worried about that. Here are a couple of pictures - they are not the best - it is an awkward area. Just a couple of additional notes: the rafters are 2x4s and sit on the top plate with a bird's mouth cut. The present door is actually 24 inches, not 28. The king on the right side of the door will stay, the jack will have to be replaced, and the king and jack will have to be replaced and moved to the left on the left side; new header and cripples; no other framing will be touched. That wiring was not done by me and will be removed as part of this project. Thanks for the help.
Last edited by Windows; 02-01-2013 at 04:22 PM. Reason: clarification |
|
|
|
|
|
#4 |
|
Member
Join Date: Jan 2013
Posts: 197
|
Temporary support wall question
U will be fine u can either do header same way Just longer or u could do 2x6 or 2x8 as header rough opening 2 1/4 in bigger than door ( 2' 8" door = 34 1/4 in rough opening
|
|
|
|
| The Following User Says Thank You to kaschmid3 For This Useful Post: | Windows (02-01-2013) |
|
|
#5 |
|
journeyman carpenter
Join Date: Sep 2011
Location: nova scotia canada
Posts: 2,239
|
Temporary support wall question
with that small an opening not much is going to happen, you should be fine without a temp wall. if you were talking 5' then the wall would be a good idea
|
|
|
|
|
|
#6 |
|
Moderator
Join Date: Mar 2009
Posts: 8,843
|
Temporary support wall question
I'd just stick a 2x4 under the rafter (or two) a few feet from the door/wall to give working room, at a 60* angle. Safety - to keep that section of probably over-spanned rafters/roof from sagging when you remove the existing header to grow 8-10 inches more. BTW- the paper facing on the batts is facing the wrong way- though it is stopping wind-washing.
Gary
__________________
Clothes taking longer to dry?
Clean the dryer screen in HOT water if using fabric softener sheets. They leave a residue that impedes air-flow, costing you money. Clean the ducting in the last six months? 17,000 dryer fires annually! |
|
|
|
|
|
#7 | |
|
Member
Join Date: Feb 2010
Location: South Seattle
Posts: 507
|
Temporary support wall questionQuote:
|
|
|
|
|
| The Following User Says Thank You to Windows For This Useful Post: | Gary in WA (02-03-2013) |
![]() |
| Thread Tools | Search this Thread |
| Display Modes | |
|
|
Similar Threads
|
||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| Load bearing wall removal question... | Huggins90 | Building & Construction | 17 | 01-21-2013 11:07 AM |
| How to add temporary support to this wall (to open up this wall)? | jsunsun | Building & Construction | 7 | 01-20-2013 10:36 PM |
| Temporary brace wall for Cathedral / Vaulted ceiling | FCdiy | Building & Construction | 2 | 11-04-2011 12:12 AM |
| load-bearing wall question | gbrady | Remodeling | 5 | 04-08-2011 12:22 PM |
| Raising Doorway Height (load bearing?) | treefrog | Building & Construction | 6 | 02-25-2008 10:11 PM |