Roof sheathing


Does anyone here know if it is code compliant to use 7/16" OSB for roof sheating in NYS?

Thanks

Advertisement

NASCARFANGO88 is offline   Reply With Quote
Old 04-01-2013, 11:06 PM   #2
Roofmaster
 
Join Date: Oct 2012
Location: Maryland
Posts: 3,669
Rewards Points: 2,096
Default

Roof sheathing


Do your local authorities having jurisdiction go by the IBC?

Personally, I would not even think about it. Just because you can does not mean that you should.

Advertisement

__________________
" A lot of men build things, and a lot of things fall down "

jagans is offline   Reply With Quote
The Following User Says Thank You to jagans For This Useful Post:
NASCARFANGO88 (04-03-2013)
Old 04-01-2013, 11:19 PM   #3
Member
 
GBrackins's Avatar
 
Join Date: Apr 2012
Location: Fairhaven, Massachusetts
Posts: 2,877
Rewards Points: 2,032
Default

Roof sheathing


if you'd like a nice ripple effect to your roof ..... then 7/16" would be perfect. I never specify anything less than 5/8"

here are the building codes for NY state http://publicecodes.cyberregs.com/st...010-999999.htm
__________________
Gary

"You get what you pay for, and sometimes free costs more!"
GBrackins is offline   Reply With Quote
The Following 2 Users Say Thank You to GBrackins For This Useful Post:
NASCARFANGO88 (04-03-2013), woodworkbykirk (04-02-2013)
Old 04-01-2013, 11:27 PM   #4
Newbie
 
Join Date: Apr 2013
Posts: 5
Rewards Points: 10
Default

Roof sheathing


I believe they do go by the IBC.

Thanks
NASCARFANGO88 is offline   Reply With Quote
Old 04-01-2013, 11:32 PM   #5
Newbie
 
Join Date: Apr 2013
Posts: 5
Rewards Points: 10
Default

Roof sheathing


Well, its just a small addition and I have a lot of 7/16" OSB and a lot of scrap 2x4's. What I was going to do was put a 2x4 every 16" between the trusses I know its a lot of extra work but it would stop the rippling effect I think. Also, 5/8" plywood here is $26 a sheet and I need 12. Is this a bad idea?
NASCARFANGO88 is offline   Reply With Quote
Old 04-01-2013, 11:33 PM   #6
Member
 
GBrackins's Avatar
 
Join Date: Apr 2012
Location: Fairhaven, Massachusetts
Posts: 2,877
Rewards Points: 2,032
Default

Roof sheathing


oh, and I forgot ...... Welcome to the Forum! Go #24
__________________
Gary

"You get what you pay for, and sometimes free costs more!"
GBrackins is offline   Reply With Quote
The Following User Says Thank You to GBrackins For This Useful Post:
NASCARFANGO88 (04-03-2013)
Old 04-02-2013, 06:12 AM   #7
journeyman carpenter
 
woodworkbykirk's Avatar
 
Join Date: Sep 2011
Location: nova scotia canada
Posts: 2,766
Rewards Points: 2,148
Default

Roof sheathing


we use no less than 5/8 we'll even go as far as using 3/4" t &g plywood, but 7 /16 no thanks too flimsy
woodworkbykirk is offline   Reply With Quote
The Following User Says Thank You to woodworkbykirk For This Useful Post:
NASCARFANGO88 (04-03-2013)
Old 04-02-2013, 08:14 AM   #8
Exterior Construction
 
Windows on Wash's Avatar
 
Join Date: Aug 2011
Location: Washington DC Metro Area (VA, MD, DC)
Posts: 7,089
Rewards Points: 3,244
Default

Roof sheathing


+1 to the other posters.

Even if it were permitted...don't do it. Go thick and do it once. Your roof and structure will thank you.
Windows on Wash is offline   Reply With Quote
The Following 2 Users Say Thank You to Windows on Wash For This Useful Post:
NASCARFANGO88 (04-03-2013), woodworkbykirk (04-02-2013)
Old 04-03-2013, 02:02 AM   #9
Newbie
 
Join Date: Apr 2013
Posts: 5
Rewards Points: 10
Default

Roof sheathing


I would like to thank everyone for their input, and I will take back the 7/16" osb back and get 5/8" plywood even though its double the price now, it will be worth it for the long haul.

Thanks

Advertisement


Last edited by NASCARFANGO88; 04-03-2013 at 02:07 AM.
NASCARFANGO88 is offline   Reply With Quote
The Following 2 Users Say Thank You to NASCARFANGO88 For This Useful Post:
fetzer85 (04-03-2013), GBrackins (04-03-2013)
Reply


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
Roof Sheathing mrus Roofing/Siding 8 04-07-2012 07:59 PM
is my sheathing rotting? *pics* Nospammer Roofing/Siding 24 03-07-2012 10:06 PM
Roof Sheathing Thickness Clutchcargo Building & Construction 8 09-23-2009 02:13 PM
The moving Ice Dams after using a roof rake ?? Canufixit Roofing/Siding 9 02-05-2009 08:33 PM
Rubber Roof and Roof Deck vianak Roofing/Siding 2 10-09-2008 06:37 PM




Top of Page | View New Posts