Large metal "tabs" in openings cut in bi-level rim joist... What are they? Insulate?


While replacing the drop ceiling in my bi-level, I noticed openings cut into the rim joist... I see rounded metal "tabs" sticking through, what appears to be the back of our aluminum siding, and can feel lots of cold air around them. Pictures below.

The rim joists currently have no insulation. And our basement gets damn cold in the winter; could these openings be the main culprit? Should I 1) insulate fully, using thick, rigid foam blocks around the whole basement ceiling? 2) Regardless of that, at least fill in these openings with spray foam?

Of note is that we do have a gas furnace, dryer, and water heater all downstairs (utility room is one room away from the family room where I see these rim joist openings)... I read that if we seal "too" well it could cause airflow/combustion issues. Any concern there?

I just don't know enough about construction to know exactly what these openings and metal tabs are for (what are they?), and I'm sure one of you can look at the pics and know immediately what I'm talking about. Any advice would be much appreciated. Thanks!










nutlog is offline   Reply With Quote
Old 11-07-2009, 04:28 PM   #2
Member
 
Join Date: Jan 2009
Location: South of Boston, MA
Posts: 17,248
Rewards Points: 2,000
Default

Large metal "tabs" in openings cut in bi-level rim joist... What are they? Insulate?


Do they appear strong enough to have listed part of the house into place?
Wondering of the house was built off-site in pieces & then trucked there & lifted into place

Scuba_Dave is offline   Reply With Quote
Old 11-07-2009, 04:36 PM   #3
nap
You talking to me?
 
nap's Avatar
 
Join Date: Dec 2007
Location: sw mi
Posts: 5,407
Rewards Points: 2,000
Default

Large metal "tabs" in openings cut in bi-level rim joist... What are they? Insulate?


Quote:
Originally Posted by Scuba_Dave View Post
Do they appear strong enough to have listed part of the house into place?
Wondering of the house was built off-site in pieces & then trucked there & lifted into place

OOH, OOOH, OOOOH.


panelized basement walls. They are set in place with a crane or large lift of some sort.

nap is offline   Reply With Quote
Old 11-07-2009, 05:23 PM   #4
Member
 
Join Date: Mar 2009
Location: Pennsylvania
Posts: 719
Rewards Points: 500
Default

Large metal "tabs" in openings cut in bi-level rim joist... What are they? Insulate?


Maybe the house is a Modular house and the openings are where the slings were placed and removed after setting the unit on the foundation.

Just a guess I have seen this process several times.
SULTINI is offline   Reply With Quote
Old 11-07-2009, 07:42 PM   #5
Member
 
Join Date: Oct 2009
Posts: 48
Rewards Points: 25
Default

Large metal "tabs" in openings cut in bi-level rim joist... What are they? Insulate?


My guess is panalized basement walls. It looks to me that the builder wasn't able to remove the crane loops so he bent them down and notched the floor rim to bury it in the wall. I personally would have just cut them off, but it looks like that wasn't something that he wanted to do. I would just cut some extruded foam and fill the hole and then insulate the rim. I would say to just use great stuff but it might push your siding out.

As far as it being unsafe to insulate the rim, that is more of a concern if the house is very air tight. Judging by the photos, I am pretty sure that you don't have a house that is too air tight. I would just make sure that the exhaust pipes for your funace and hot water heater are in good condition and then try to seal up the rim of your house.
RobQuillin is offline   Reply With Quote
Old 11-08-2009, 07:53 AM   #6
Member
 
Join Date: Mar 2009
Location: Pennsylvania
Posts: 719
Rewards Points: 500
Default

Large metal "tabs" in openings cut in bi-level rim joist... What are they? Insulate?


NAP Not here to dispute you however as my post states I have seen many modulars lifted this way.

Yes they arrive on site on a metal framed trailer ready for pick up.

There are large slings with spreader bars that run under the bottom plate cutouts, when the half of house is lifted the crane is lowered and the slings are removed and the 2x6 (yes 2x6) pieces of bottom plate are placed back.

Then the other half is placed and pulled together with binders.

Then all the other stages are completed.

Now I am not disagreeing the issues of cast placement I am just giving Modular information.

I actually think they are for lifting cast because Modular cutouts would be neat and almost perfect the cuts in the picture appear to be sloppy.
SULTINI is offline   Reply With Quote
Old 11-08-2009, 02:32 PM   #7
Member
 
Join Date: Nov 2009
Location: central virginia mountains
Posts: 1,857
Rewards Points: 1,000
Default

Large metal "tabs" in openings cut in bi-level rim joist... What are they? Insulate?


please check with your gas company to make sure you have adequate air for gas appliances after you insolate. flame will seek out air if it is not at burner
tpolk is offline   Reply With Quote
Old 11-09-2009, 07:01 AM   #8
Mold!! Let's kill it!
 
Join Date: Feb 2008
Location: Central Pennsylvania
Posts: 2,849
Rewards Points: 2,012
Default

Large metal "tabs" in openings cut in bi-level rim joist... What are they? Insulate?


To the OP, I would get a can of low expansion foam and fill those voids. That will stop the air infiltration.
Maintenance 6 is offline   Reply With Quote
Old 11-09-2009, 03:13 PM   #9
Newbie
 
Join Date: Dec 2008
Posts: 25
Rewards Points: 10
Default

Large metal "tabs" in openings cut in bi-level rim joist... What are they? Insulate?


Thanks for the replies. I had already picked up a can of Great Stuff, but hadn't thought about the possibility of it expanding and pushing the siding out. I'll go exchange it for the door/window stuff, which doesn't expand.

Lack of airflow is not a problem, at least right now... the ground level of the house (not a basement; the lower level is fully above ground) is still a good 10-15 degrees colder than upstairs. It's really poorly insulated, air leaks around doors, and of course these big holes in the rim we just found. So as long as it's safe to insulate the rim, I'll stick some 2" rigid foam around, on top of those spray foamed holes.

For reference, when insulating the rim, do I need to just do the 2 opposing sides (small blocks where all the joists meet the rim)? Or also the wall perpendicular to those, which is also an outside wall, that runs parallel to the joists (with a long rectangle block)? Thanks!
nutlog is offline   Reply With Quote
Old 11-09-2009, 03:19 PM   #10
Mold!! Let's kill it!
 
Join Date: Feb 2008
Location: Central Pennsylvania
Posts: 2,849
Rewards Points: 2,012
Default

Large metal "tabs" in openings cut in bi-level rim joist... What are they? Insulate?


Do everything that has an outside exposure. If you cut your rigid stuff ahead of time, you can use the low ex stuff as an adhesive to keep it in place.

Maintenance 6 is offline   Reply With Quote
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
Insulate joist bays along with radiant heat, how ? iMisspell Building & Construction 2 12-08-2008 12:17 PM
Filling in large openings in concrete foundation shtoink Building & Construction 10 12-04-2008 04:03 PM
Wire size for 300watt trans, 3 way 100ft Al the Diy guy Electrical 16 03-22-2008 08:46 PM




Top of Page | View New Posts

Copyright © 2003-2014 Escalate Media. All Rights Reserved.