garage firewall question


i want to re do my firewall because the drywall near the floor is rotted out or missing sections and mice can get in. also they had a huge fan the has a huge opening into the attic to pull the hot air out. so none the less the wall is not completly sealed off for fire reasons but mice and gases getting into the house as well. what do i all need to do it proper and to code? 1/2 or 5/8" dryall?? also do i need plastic for a weather barrier? thanks

jhack836 is offline   Reply With Quote
Old 06-15-2012, 05:00 PM   #2
Member
 
Join Date: Apr 2012
Location: UK
Posts: 709
Default

garage firewall question


Quote:
Originally Posted by jhack836 View Post
i mice and gases getting into the house as well. what do i all need to do it proper
mice?
Attached Thumbnails
garage firewall question-scan0080.jpg  

tony.g is online now   Reply With Quote
Old 06-15-2012, 05:03 PM   #3
Member
 
Join Date: Jan 2012
Location: LI, NY
Posts: 112
Default

garage firewall question


5/8 type x is what's most commonly used. Vapor barrier on the garage side is probably the wrong side but it depends on where you live.don't forget to address the issue that caused it to rot out in the first place
eclark is offline   Reply With Quote
Old 06-15-2012, 05:25 PM   #4
Member
 
Join Date: Jun 2012
Posts: 113
Default

garage firewall question


agree 5/8ths
hotrod351 is offline   Reply With Quote
Old 06-15-2012, 06:25 PM   #5
Haverhill Trade 1965
 
Join Date: Mar 2012
Location: New Hampshire
Posts: 532
Default

garage firewall question


Quote:
Originally Posted by tony.g View Post
mice?
Is that a mice or gasses trap? I'm confused.
Duckweather is offline   Reply With Quote
Old 06-15-2012, 07:20 PM   #6
Member
 
Join Date: Nov 2011
Location: Hartfield VA
Posts: 25,575
Default

garage firewall question


If the drywall was installed tight to the floor there's the reason it failed.
It needed to be about 1/2" up off the concrete.
Mice will just eat right through and new drywall.
Need to address this mice problum.
joecaption is online now   Reply With Quote
Old 06-15-2012, 07:43 PM   #7
Member
 
GBrackins's Avatar
 
Join Date: Apr 2012
Location: Fairhaven, Massachusetts
Posts: 2,800
Default

garage firewall question


agree, 5/8" type X fire rated gypsum board. If you cannot cover the holes that the mice are getting in try packing them with steel wool (and throw a few moth balls in the holes, mice hate them).
__________________
Gary

"You get what you pay for, and sometimes free costs more!"
GBrackins is online now   Reply With Quote
Old 06-15-2012, 08:06 PM   #8
Member
 
Join Date: Feb 2012
Posts: 248
Default

garage firewall question


Quote:
Originally Posted by GBrackins View Post
agree, 5/8" type X fire rated gypsum board. If you cannot cover the holes that the mice are getting in try packing them with steel wool (and throw a few moth balls in the holes, mice hate them).
im trying to find my camera to show you what i have going on, i mean itl be real easy to re do. i just want to make sure i re do it right and to code.
jhack836 is offline   Reply With Quote
Old 06-16-2012, 08:15 AM   #9
Member
 
Join Date: Feb 2012
Posts: 248
Default

garage firewall question


the 1st pic you can see that huge fan. so i have the huge hole in the wall for the fan that is useless. the 2nd pic is along the floor behind the stairs. that is pretty much how it is the whole way along the floor.
Attached Thumbnails
garage firewall question-img_2062.jpg   garage firewall question-img_2061.jpg  
jhack836 is offline   Reply With Quote
Old 07-14-2012, 05:22 PM   #10
Member
 
Join Date: Feb 2012
Posts: 248
Default

garage firewall question


Quote:
Originally Posted by GBrackins View Post
agree, 5/8" type X fire rated gypsum board. If you cannot cover the holes that the mice are getting in try packing them with steel wool (and throw a few moth balls in the holes, mice hate them).
ok i am getting ready to tear down that wall and take that fan out as well. i know i need 5/8'' fire rated drywall and fire resistant drywall tape. if insolation is good i will leave it unless mice got to it. few questions though..

1. should i leave the drywall 1/2" off the concrete floor? i want it to fire and gas tight as well as no mice getting back in.

2. should i just drywall to the studed wall or should i put some vapor barrier if the interior wall doesnt have any?

either way the new wall will be alot better than what i have now. alot gaps, all exposed seams and the huge hole in the wall for that fan

Last edited by jhack836; 07-14-2012 at 05:27 PM.
jhack836 is offline   Reply With Quote
Old 07-14-2012, 11:13 PM   #11
JOATMON
 
ddawg16's Avatar
 
Join Date: Aug 2011
Location: S. California
Posts: 6,756
Default

garage firewall question


Quote:
Originally Posted by jhack836 View Post
ok i am getting ready to tear down that wall and take that fan out as well. i know i need 5/8'' fire rated drywall and fire resistant drywall tape. if insolation is good i will leave it unless mice got to it. few questions though..

1. should i leave the drywall 1/2" off the concrete floor? i want it to fire and gas tight as well as no mice getting back in.

2. should i just drywall to the studed wall or should i put some vapor barrier if the interior wall doesnt have any?

either way the new wall will be alot better than what i have now. alot gaps, all exposed seams and the huge hole in the wall for that fan
1. You don't want the drywall to touch the floor. 1/2" is good....

2. The vapor barrier needs to be on the inside. You do NOT want to add a vapor barrier on the garage side.
__________________
"The dream is free but the hustle is sold separately."

My 2-Story Addition Build in Progress Link ... My Garage Build Link and My Jeep Build Link
ddawg16 is offline   Reply With Quote
Old 07-15-2012, 09:00 AM   #12
Member
 
Join Date: Feb 2012
Posts: 248
Default

garage firewall question


Quote:
Originally Posted by ddawg16 View Post
1. You don't want the drywall to touch the floor. 1/2" is good....

2. The vapor barrier needs to be on the inside. You do NOT want to add a vapor barrier on the garage side.
ok thanks. do i really need a vapor barrier if there is not one. i have no idea if they have one or not, im guessing now as i see how alot of thing were done around here.

also what is the difference with a vapor barrier on the inside vs garage side?

i want to add a outlet and the one i have is not grounded so i want to run a whole new line from the breaker box. do i need any special fire rated boxes and or wires? im guessing they should be at least in a conduit
jhack836 is offline   Reply With Quote
Old 07-15-2012, 09:37 AM   #13
Residential Designer
 
AndyGump's Avatar
 
Join Date: Sep 2010
Location: Orange County CA.
Posts: 1,253
Send a message via Skype™ to AndyGump
Default

garage firewall question


From the 2009 IRC.

Andy.
Attached Thumbnails
garage firewall question-2009-irc.jpg  
__________________
Residential Drafter/Designer
www.draftinginoc.com
AndyGump is offline   Reply With Quote
Old 07-15-2012, 06:49 PM   #14
Member
 
Join Date: Feb 2012
Posts: 248
Default

garage firewall question


Quote:
Originally Posted by AndyGump View Post
From the 2009 IRC.

Andy.
thanks, there is no vapor barrier on interior wall. just drywall on each side of the studded wall with insolation. the garage side has that backer board stuff then the drywall though. i will be tearing that out, was that just for extra protection from fire because the drywall currently is only 1/2"?
jhack836 is offline   Reply With Quote
Old 07-16-2012, 12:01 PM   #15
Mold!! Let's kill it!
 
Join Date: Feb 2008
Location: Central Pennsylvania
Posts: 2,830
Default

garage firewall question


The backer board stuff was probably for shear resistance. If you tear that out, you need to replace it. 3/8 or 1/2 plywood or 1/2 OSB depending on the age of the home.

Maintenance 6 is offline   Reply With Quote
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
Adding Mudroom in exisiting garage - Foundation question screamon demon Building & Construction 2 02-02-2011 12:30 PM
question about wiring basement with garage panel 1acman Electrical 4 01-19-2011 11:44 AM
Garage Heater Wiring ceiling penetration Question DenverBob Electrical 5 12-28-2009 01:01 PM
Garage insulation question trojanman1 Building & Construction 7 09-16-2009 02:51 PM
Carport to Garage: Fire barrier question Grommet Remodeling 2 03-28-2008 04:18 PM




Top of Page | View New Posts

Copyright © 2003-2014 Escalate Media. All Rights Reserved.