Dryer Venting question (Another one)


I need to install / re-run our dryer vent for our electric dryer. It appears to have been disconnected or poorly installed and gets no air out of the vent at the side of our house.

The existing one has a long run, probably 30 feet or so. It goes down through the floor and then makes 90 and takes the straight shot to the side of the house over a bathroom and a bedroom.

The people that installed it used a combination of flex metal duct and flex vinyl duct. This repair will probably involve breaking out some drywall. I don't see any other opportunities to steer it to another exterior wall or out the roof.

As far as materials for the vent:
Is pvc suitable for this? How about rigid tin without using screws? Flex duct has always seemed inferior for this type of use. Maybe it's just me.

Thanks in advance.

brokenhammer is offline   Reply With Quote
Join DIYChatroom.com

Join the #1 DIY Forum Today - It's Totally Free!

DIYChatroom.com - Are you about to start a new home improvement task and need some help? Do you need advise on what products to buy? Or maybe you can give others some advice? No matter where you fit in you'll find that DIY Chatroom is a great community to join. Best of all it's totally free.

Join DIYChatroom.com - Click Here
JOIN FOR FREE


Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. DIYChatroom.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any home improvement task!
Old 07-05-2012, 10:15 AM   #2
Member
 
Join Date: Jan 2009
Location: WV
Posts: 2,124
Default

Dryer Venting question (Another one)


I have never used flex metal duct for a dryer exhaust so can't say whether or not it's a good idea. The flex vinyl, on the other hand, would be a very poor choice. I don't think it's code legal for dryers and I'm not sure you can even buy it any more. Nor would I use PVC.

Dryers usually have some specification for how long the exhaust run can be, how many bends, etc. I may be wrong, but 30 ft seems a bit long to me. You might want to consider a booster fan.

md2lgyk is offline   Reply With Quote
Old 07-05-2012, 10:16 AM   #3
Member
 
joed's Avatar
 
Join Date: Mar 2005
Location: Welland, Ontario
Posts: 6,037
Default

Dryer Venting question (Another one)


Do not use flex. I don't think PVC is permitted as it is flammable. The solid tin or aluminum pipes duct taped with real duct tape(the metal stuff) would be my choice.
__________________
Do not PM with questions that can be asked in a forum. I will not respond.
joed is offline   Reply With Quote
The Following User Says Thank You to joed For This Useful Post:
drtbk4ever (07-05-2012)
Reply


-->
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
Bathroom Fan Venting Question elliotriley Roofing 5 03-26-2012 09:23 PM
Venting dryer to exterior wall. jujumlnr General Discussion 8 10-17-2011 04:42 PM
Yet another bathroom exhaust fan venting question JulesB HVAC 23 03-10-2011 04:16 PM
Venting question. Bcoleman6 Plumbing 7 03-21-2008 04:41 PM
Dryer Vent Question jlaky2000 HVAC 2 03-13-2008 09:22 PM


Top of Page | View New Posts


All times are GMT -4. The time now is 07:06 PM.


© 2003 - 2010 The Building Network LLC