wiring design/box fill question


I'm doing some renovations and want to replace a ceiling fan/light combo with 3 flush mount light fixtures. The fixtures will run in a straight line about 12-15 inches apart. I had planned to wire all 3 fixtures in serial but the problem is that the line in is on the center fixture. My first thought was to branch the outer lights directly from the center box but after doing some research online i'm now worried about box fill.

by my calculations i would have:

6 14-2 conductors (2 for the line in + 4 out)
1 for the ground
1 for the light mounting strap (i'm assuming this is what NEC refers to as luminaire stud or hickey?)

this would total 16 cubic inches. i'm using 4x1.5 octagon box listed at 15.8 cubic inches.

so here are my questions:

1) Are my calculations right? is this box too small for the wiring configuration?

2) Assuming the box is too small, it seems like i would have a couple different options a) get a deeper box (assuming it fits) b) splice only a single light from the center fixture and then splice the two outer lights together c) run a second line in from the junction box directly to one of the outer lights d) any other ideas i may have missed

will all of these work? Is there a preffered option or are they all the same?

mjt610 is offline   Reply With Quote
Old 12-03-2012, 10:38 AM   #2
A "Handy Husband"
 
rjniles's Avatar
 
Join Date: Feb 2007
Location: South Carolina Low Country
Posts: 4,040
Rewards Points: 20
Default

wiring design/box fill question


Since the boxes are only 12-15" apart, run from the center box to to the left box, and then run from there back past the center to the right box. Avoids all the congestion in one box.

__________________
Location:
Coastal South Carolina
rjniles is online now   Reply With Quote
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
208V/3 Phase Wiring Question efalcon1 Electrical 12 09-28-2012 11:22 AM
Outdoor Wiring Question OKDrew63 Electrical 30 08-14-2012 11:25 PM
Adding 2 outlets in the middle of a series of outlets - wiring question Evan55 Electrical 7 06-14-2012 09:43 AM
Hot Tub Wiring Question - Wire Type? AidanD55 Electrical 10 03-18-2012 12:16 AM
Attic wiring question everyman Electrical 4 07-07-2009 09:47 AM




Top of Page | View New Posts

Copyright © 2003-2014 Escalate Media. All Rights Reserved.