Old 11-10-2009, 06:18 PM   #16
Member
 
Join Date: Oct 2007
Posts: 2,294
Rewards Points: 1,000
Default

Too much NM cable sheath inside j-box?


Quote:
I'm looking forward to a reply to scuba_dave's question on soldering
Seems dumb. Seems like a waste of time.


My grandfather used to solder wires but wiring methods in the 30's were a bit different than today.

Advertisement

220/221 is offline   Reply With Quote
Old 11-10-2009, 07:33 PM   #17
Member
 
Join Date: Sep 2007
Posts: 192
Rewards Points: 150
Default

Too much NM cable sheath inside j-box?


just make up the box like this.....
Attached Thumbnails
Too much NM cable sheath inside j-box?-box-1-medium-.jpg   Too much NM cable sheath inside j-box?-box-2-medium-.jpg  
steve1234 is offline   Reply With Quote
Old 11-10-2009, 07:36 PM   #18
Member
 
Join Date: Sep 2007
Posts: 192
Rewards Points: 150
Default

Too much NM cable sheath inside j-box?


sorry...hit submit before finishing the post. The above pic was an example of the electrical nightmare I ripped out of my house during a re-build. I saved it to show my inspector....he said he hadn't seen anything that bad in quite some time.
steve1234 is offline   Reply With Quote
Old 11-10-2009, 11:37 PM   #19
Member
 
Join Date: Oct 2007
Posts: 2,294
Rewards Points: 1,000
Default

Too much NM cable sheath inside j-box?


Quote:
he said he hadn't seen anything that bad in quite some time.
I wish I could say the same thing.
220/221 is offline   Reply With Quote
Old 11-10-2009, 11:46 PM   #20
Wire Chewer
 
Red Squirrel's Avatar
 
Join Date: Jun 2009
Location: Ontario, Canada
Posts: 3,221
Rewards Points: 2,020
Default

Too much NM cable sheath inside j-box?


LOL is it even possible to hook up those two type of boxes together the way those are, or is that jury rigged? lol
Red Squirrel is offline   Reply With Quote
Old 11-11-2009, 06:32 AM   #21
Chaos Engineer
 
Big N8's Avatar
 
Join Date: Oct 2009
Location: Coon Rapids MN
Posts: 183
Rewards Points: 150
Default

Too much NM cable sheath inside j-box?


Quote:
Originally Posted by steve1234 View Post
just make up the box like this.....

Looks Great...
<.<
>.>


LOL



But for real if you box looks like that please fix it.
Big N8 is offline   Reply With Quote
Old 11-11-2009, 01:13 PM   #22
Member
 
Join Date: Sep 2007
Posts: 192
Rewards Points: 150
Default

Too much NM cable sheath inside j-box?


bigN8...no, it doesn't currently look like that. That was just one example of the "before". In our project I had every wall opened up, re-wired 90% of the house and the other 10% I was able to see and verify it was ok. Everything permited / inspected / passed to the 2005 NEC.
steve1234 is offline   Reply With Quote
Old 11-11-2009, 02:35 PM   #23
Member
 
Join Date: May 2009
Location: Brooklyn, New York (NYC)
Posts: 1,124
Rewards Points: 500
Smile

Too much NM cable sheath inside j-box?


Quote:
Originally Posted by Red Squirrel View Post
LOL is it even possible to hook up those two type of boxes together the way those are, or is that jury rigged? lol
Theoretically, I believe it is legal. It's both, jury-rigged and workable. Some 1900 boxes have a template/knockout the size and shape of a (jamb) box in the back. (No matter what) Don't Drink and Drive, Ever!!!
spark plug is offline   Reply With Quote
Old 11-11-2009, 04:01 PM   #24
Wire Chewer
 
Red Squirrel's Avatar
 
Join Date: Jun 2009
Location: Ontario, Canada
Posts: 3,221
Rewards Points: 2,020
Default

Too much NM cable sheath inside j-box?


Wow but probably better using an extender the same size as the stove/dryer box type lol.
Red Squirrel is offline   Reply With Quote
Old 11-11-2009, 04:27 PM   #25
Member
 
Join Date: Jan 2009
Location: South of Boston, MA
Posts: 17,248
Rewards Points: 2,000
Default

Too much NM cable sheath inside j-box?


Quote:
Originally Posted by steve1234 View Post
bigN8...no, it doesn't currently look like that. That was just one example of the "before"
I'd be curious as to how many (and types of) wires were in that box & if it was even close to code for box fill

Advertisement

Scuba_Dave is offline   Reply With Quote
Reply

Tags
junction box , nm cable sheath


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
Cable question tommy_vercetti Home Theater 15 09-26-2009 10:10 AM
Underground service entrance cable requirements. kgt55 Electrical 9 06-22-2009 07:55 AM
Satellite vs. cable coaxial types? Badfish740 Home Theater 6 02-17-2009 12:00 PM
four wires inside a cable?! joeyboy Electrical 23 11-05-2007 11:31 AM
Coaxial Cable Question bahaisamurai Home Theater 9 08-08-2007 03:54 PM