mobiledynamics 03-30-2012 11:45 PM

Securing MC/AC cable to existing outlet box
 
Standard 4" Steel Box in Wall.
I suppose a good wack of a flathead screw will be able to get a knockout out.

I plan to run a new line to this box if doable...

Do they make special fittings that I can use to secure a BX cable in a 1/2 knockout or 3/4 ........that I can secure to the box IF I only have access to the *inside* of the box ?

k_buz 03-30-2012 11:52 PM

Put the connector on before fishing it down the wall.

Otherwise, they make snap in connectors for MC that don't use a locknut.

jlmran 03-30-2012 11:55 PM

Put a connector onto the flex before you fish it to the box. Then have the nut handy to screw onto the connector. ???

mobiledynamics 03-31-2012 12:00 AM

Genius - on putting the connector on the cable before fishing it ! I did not even think about doing it this way...

jlmran 03-31-2012 12:08 AM

This forum has an echo...

mobiledynamics 03-31-2012 09:16 PM

Any secret sauce advice on knocking out the knockout from the inside of the box.

It's a tile backsplash so I want to keep vibration to a minimum...

sublime2 03-31-2012 09:37 PM

Quote:

Originally Posted by mobiledynamics (Post 889387)
Any secret sauce advice on knocking out the knockout from the inside of the box.

It's a tile backsplash so I want to keep vibration to a minimum...


Flat head screwdriver.
Push on tab to bend it,once it bends rock it back and forth till it snaps off.