Olgian77 06-24-2012 05:04 AM

Samsung TV Extension Power cord
 
I need to buy a 15' power cord for my new Samsung TV with an L-shape that plugs into the TV.
Where can I find that?

stickboy1375 06-24-2012 06:21 AM

Quote:

Originally Posted by Olgian77 (Post 950124)
I need to buy a 15' power cord for my new Samsung TV with an L-shape that plugs into the TV.
Where can I find that?

I would start with Samsung... Give them a call.

garyoutwest 06-24-2012 06:27 AM

"L" shaped like this?

13ra_1.jpeghttp://www.americord.com/media/catal...0c-13ra_1.jpeg

That is on this site:
http://www.americord.com/media/catalog/category/5-15p_20to_20c-13ra_1.jpeg

But if this is it, they are pretty common. Any decent electronics store or department should have them.

Gary

mpoulton 06-24-2012 12:14 PM

Search around online (Amazon and Newegg would be good places to look) for "IEC" cords. That's the name of the standard power connector on the TV.

gregzoll 06-24-2012 12:59 PM

monoprice, radioshack, partsexpress. Also, you are better locating a outlet nearer to the tv, than run a 15 foot cord.

CopperClad 06-24-2012 04:15 PM

Agreed. Pretty sure the code stating an outlet every 6' are to prevent people from running 15' extension cords to their tv's.

k_buz 06-24-2012 04:46 PM

There is no such code requiring an outlet every 6 feet.:no:

CopperClad 06-24-2012 05:04 PM

NEC2005 Article 210.52(A)(1)SPACING. Recepticles shall be installed so that no point measured horizontally along the floor line in any wall space is more than 1.8m(6') from a recepticle outlet. Also NEC2005

CopperClad 06-24-2012 05:12 PM

sorry. I think I copy and pasted that from a yahoo answer.. I can't find it but I could have swore in the 2011 NEC update they changed it to 6'.. :whistling2:

k_buz 06-24-2012 08:40 PM

Nope:no:

gregzoll 06-24-2012 09:11 PM

Here k_buz, since you seem to think that it is FUD:

http://www.ezdiyelectricity.com/?p=95 I will give you a clue. 210.52(A)

CopperClad 06-24-2012 09:14 PM

Yeah, that's the old one I posted as well.. I could have swore I read some where that they did change it to every 6' in the 2011 update.. I couldn't find it though.. And I'm not paying to download it. I gave up looking. So I guess it's still the same..

k_buz 06-24-2012 09:21 PM

Quote:

Originally Posted by gregzoll (Post 950854)
Here k_buz, since you seem to think that it is FUD:

http://www.ezdiyelectricity.com/?p=95 I will give you a clue. 210.52(A)

And I suppose you install counter top receptacles every 2' as well.

Quote:

(1) Spacing. Receptacles shall be installed such that no
point measured horizontally along the floor line in any wall
space is more than 1.8 m (6 ft) from a receptacle outlet.
Can you tell me where it says that outlets have to be spaced 6' apart?

Jim Port 06-24-2012 09:47 PM

You won't find the change to every 6'. It was not changed.

stickboy1375 06-25-2012 04:38 AM

I love the imaginary code sightings we get on here. :no: