New Panel
I have a house from the 1960's and my 15 amp wires has:
1. kind of teal/greenish scale sheathing
2. marked with "14/2 With Ground Type NM"
3. black, while and ground (ground wire is thinner than the others)
My 20 amp wires have:
1. kind of teal/greenish scale sheathing
2. marked with "12/2 With Ground Type NM" or "12/3 With Ground Type NM"
3. "12/2" wire has black, while and ground. Ground wire is again thinner than the others but overall they are stiffer and thicker than 14/2 wires
4. "12/3" also has a red wire
If I was not sure of the circuit size, I woud try what MB said, but I would also be cautious and install 15 amp breakers on all of them for the time being.
Good luck
PS. If it's new, the sheathing might be white (14 awg) or yellow (12 awg) but read the print on the sheathing to make sure
Last edited by allthumbsdiy; 09-22-2012 at 10:59 PM.
Reason: added ps
|