Maybe a stupid question(s)


Is there anything in the code that prohibits placing lights and wall outlets on the same circuit? I know about the no other outlets on the kitchen small appliance circuits, but can the bedroom lights and outlets be together, living room outlets and lights, etc.
Another thing, on the kitchen small appliance circuit there is an exception for "Receptacles installed to provide power
for supplemental equipment and lighting on gas-fired
ranges, ovens, or counter-mounted cooking unit", does the hood/light above the stove count as "supplemental equipment"?(this is a gas stove btw)

CaneinBR is offline   Reply With Quote
Old 07-16-2009, 11:29 PM   #2
My License Ain't 4 Sale..
 
Join Date: Feb 2008
Location: Atlanta, Ga/Hamilton, Al
Posts: 1,813
Default

Maybe a stupid question(s)


Quote:
Originally Posted by CaneinBR View Post
Is there anything in the code that prohibits placing lights and wall outlets on the same circuit? I know about the no other outlets on the kitchen small appliance circuits, but can the bedroom lights and outlets be together, living room outlets and lights, etc.
Another thing, on the kitchen small appliance circuit there is an exception for "Receptacles installed to provide power
for supplemental equipment and lighting on gas-fired
ranges, ovens, or counter-mounted cooking unit", does the hood/light above the stove count as "supplemental equipment"?(this is a gas stove btw)
Yes, the lights and receptacles can be on the same circuit. I personally try to avoid that. No, the vent hood cannot be power from the appliance circuit, unless it is part of the stove itself.

InPhase277 is offline   Reply With Quote
Old 07-16-2009, 11:39 PM   #3
Learning by Doing
 
Leah Frances's Avatar
 
Join Date: Jan 2008
Location: Easton, Maryland
Posts: 3,156
Blog Entries: 7
Default

Maybe a stupid question(s)


It's nice to have recs and lights on separate circuits that way if one blows you aren't left entirely in the dark.

When I was a little girl and having trouble remembering to turn off the lights when I left a room my dad decided to take action. First he took the light bulbs out of ceiling fixture. Next, he killed power to the entire room. Little did he know that I discovered that the closet light still worked... I can still remember taking all my shoes off the shoe-shelf and sitting in the bottom of my closet and reading until the wee hours of the night.
__________________
If I could only remember to THINK about what I was doing before I did it.
Leah Frances is offline   Reply With Quote
Old 07-17-2009, 08:36 AM   #4
Registered User
 
Termite's Avatar
 
Join Date: Apr 2008
Posts: 6,520
Default

Maybe a stupid question(s)


It is very common to have the bedroom receps and lights on the same circuit, especially given the AFCI requirements for sleeping areas in pre-2008 editions of the NEC. Cheaper to do it that way!
Termite is offline   Reply With Quote
Old 07-17-2009, 12:16 PM   #5
Licensed Electrical Cont.
 
Speedy Petey's Avatar
 
Join Date: Feb 2004
Location: NY State
Posts: 6,809
Default

Maybe a stupid question(s)


Quote:
Originally Posted by Leah Frances View Post
It's nice to have recs and lights on separate circuits that way if one blows you aren't left entirely in the dark.
unless you are in the bathroom with the door closed this is rarely an issue, yet it seems to be a very popular opinion for some reason.

This opinion makes it seem like every light in the whole house is on one circuit and you would be left in pitch black if any breaker ever tripped.
I can tell you from experience, this is not usually the case.
__________________
Sometimes I feel like if I answer any more questions it is like someone trying to climb over a fence to jump off a bridge and me giving them a boost.
Answers based on the 2008 & 2011 NEC.
Speedy Petey is online now   Reply With Quote
Old 07-17-2009, 02:44 PM   #6
Newbie
 
Join Date: Jul 2009
Posts: 2
Default

Maybe a stupid question(s)


Thanks for the replies guys and gal. Couple of more questions. GFCI's are required at the front and rear of house(outside), can these be ran off of a nearby circuit or will I have to run a circuit just for them?
The bathroom is very small w/a closet, it has one gfci outlet, a light above the sink and a light in the closet. Can the "sink light" and closet light be ran off the gfci circuit? Seems like I read an exception about being able to, as long as it was the same bathroom. It's the only bath in the house. Additionally, I have a 20 amp dedicated circuit for the heater/vent/light combo in the ceiling.(for those that were wondering)
CaneinBR is offline   Reply With Quote
Old 07-17-2009, 04:34 PM   #7
Electrical Contractor
 
jbfan's Avatar
 
Join Date: Jun 2004
Location: Newnan GA
Posts: 5,747
Default

Maybe a stupid question(s)


You can use any close circuit as long it is not the small appliance circuits from the kitchen/dining room.
As long as the circuit feeding the bathroom does not leave that bathroom, the you can put the lights on that circuit
__________________
Yes I am a Pirate, 200 years too late. "Jimmy Buffett"
jbfan is online now   Reply With Quote
Old 07-17-2009, 07:19 PM   #8
Member
 
Join Date: Jan 2009
Location: South of Boston, MA
Posts: 17,248
Default

Maybe a stupid question(s)


I have 8 dedicated 20a outside circuits
Big Christmas display
I prefer my GFCI inside, protecting a reg circuit outside
Any outside outlet under NEC 2008 has to be weather resistant (WR) now
So a normal WR outlet is a LOT less then a GFCI WR

Dont forget the in-use bubble covers
Scuba_Dave is offline   Reply With Quote
Old 07-17-2009, 09:33 PM   #9
Member
 
perpetualjon's Avatar
 
Join Date: Jan 2009
Posts: 168
Default

Maybe a stupid question(s)


So it's generally normal to run separate circuits for the lighting apart from the receptacles? I guess this would mean that some bedrooms would all have their lighting run off of one breaker (as would the receptacles). I'd like to isolate each room to it's own breakers. Is this normally not done?
__________________
"...and everyone is entitled to my opinion!!"
Read more about my ongoing remodeling project
perpetualjon is offline   Reply With Quote
Old 07-17-2009, 09:48 PM   #10
Licensed Electrical Cont.
 
Speedy Petey's Avatar
 
Join Date: Feb 2004
Location: NY State
Posts: 6,809
Default

Maybe a stupid question(s)


Quote:
Originally Posted by perpetualjon View Post
So it's generally normal to run separate circuits for the lighting apart from the receptacles?
Nope, not "normal", just individual preference.

For bedrooms, living rooms, dens and similar rooms, and the occasional bath I typically mix receptacle and lighting.
__________________
Sometimes I feel like if I answer any more questions it is like someone trying to climb over a fence to jump off a bridge and me giving them a boost.
Answers based on the 2008 & 2011 NEC.
Speedy Petey is online now   Reply With Quote
Old 07-18-2009, 09:26 AM   #11
Newbie
 
Join Date: Jul 2009
Posts: 8
Default

Maybe a stupid question(s)


when you see the price of those arkfault breakers you will leave it all alone

javier is offline   Reply With Quote
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
Help How to Wire Bathroom "Fan Heater Light Night-light" unit, and questions Tryvidy Electrical 9 06-18-2012 02:37 PM
How thick should my thinset be? yummy mummy Tiling, ceramics, marble 20 09-28-2009 12:36 PM
Questions about upgrading electrical stuff in our house Trisha Electrical 8 01-16-2009 06:26 AM
Laminate wood floor layout questions nathan.tran Flooring 4 08-30-2008 10:56 PM
perhaps a stupid mortar questions amakarevic Building & Construction 5 04-24-2008 11:23 AM




Top of Page | View New Posts

Copyright © 2003-2014 Escalate Media. All Rights Reserved.