York gas heater control board replacement
 
I am having trouble with a York diamond 90 gas heater. The unit blows cold air every few days. Once the power is cycled on the unit, it works and blows hot air. A HVAC company came out and stated that the fault lights is flashing 8 times and needs a new control board. The price is about $500 installed.
I found the part online York #33101972200 for $125.
How difficult is the control board replacement? It looks like a direct swap to me.

harleyrider 03-21-2007 10:00 AM

Can you post a picture of the board?

spyvan 03-21-2007 10:45 AM

pic of replacement board
 
http://arnoldservice.com/33101972200...oard%20all.JPG

harleyrider 03-21-2007 10:51 AM

Quote:

Originally Posted by spyvan (Post 37743)


http://img.photobucket.com/albums/v1...cture_0223.jpg


Not exactly the same, but the plugs are the same

richertt 12-28-2008 11:24 AM

I have a bad control board as well. Service guy wants to charge $600.00. Where did you find your replacement board?

beenthere 12-29-2008 08:12 AM

Quote:

Originally Posted by spyvan (Post 37734)
I am having trouble with a York diamond 90 gas heater. The unit blows cold air every few days. Once the power is cycled on the unit, it works and blows hot air. A HVAC company came out and stated that the fault lights is flashing 8 times and needs a new control board. The price is about $500 installed.
I found the part online York #33101972200 for $125.
How difficult is the control board replacement? It looks like a direct swap to me.

Depending what year your furnace is.
Your board probably isn't bad.

May have a dirty flame sensor.
A bad pressure switch.
Cracked hose running to a pressure switch.
A restriction in the venting.

Usually, when the board is bad, it won't recycle and give you heat.

Look on the furnace panel, at what code 8 indicates.