unusual damper problem


I have unusual spring-open dampers that use a length of notched plastic ribbon that winds around a spool where the damper motor (a Synchron) connects (see pic at http://s14.postimage.org/x97cpmfdt/damper.jpg). Each damper blade has its own return spring (behind the orange plastic). The end of the plastic ribbon broke and the damper is now stuck in the open position.

The contractor that installed the system in 2008 is no longer in business. Another contractor that came to take a look said he'd never seen anything like this and proposed to replace the entire damper. This seems like overkill as everything but the small plastic ribbon is working fine so I'm hoping someone here can recognize the design or manufacturer.

Thanks,
Tobin

TobinB is offline   Reply With Quote
Old 01-03-2013, 12:10 PM   #2
Retired from the grind
 
gregzoll's Avatar
 
Join Date: Dec 2006
Location: Midwest - Central Illinois
Posts: 13,821
Default

unusual damper problem


If you cannot get parts, or too hard to fix, yes easier to just replace.

__________________
Ren: Now listen, Cadet. I've got a job for you. See this button? Ren: Don't touch it! It's the History Eraser button, you fool! Stimpy: So what'll happen? Ren: That's just it. We don't know. Maybe something bad, maybe something good. I guess we'll never know, 'cause you're going to guard it. You won't touch it, will you?
gregzoll is online now   Reply With Quote
Old 01-03-2013, 01:34 PM   #3
Newbie
 
Join Date: Jan 2013
Posts: 3
Default

unusual damper problem


I wouldn't mind replacing if the part was hard to find. The issue here is that I don't even know what to call it so I search for availability.
TobinB is offline   Reply With Quote
Old 01-03-2013, 01:55 PM   #4
Member
 
Join Date: Jul 2012
Location: Toronto ON
Posts: 599
Default

unusual damper problem


Can you remove it and re attach the spring? Have it riveted or welded?

It may just hook in and can be stretched slightly to re attach. Just a thought.
techpappy is offline   Reply With Quote
Old 01-03-2013, 03:49 PM   #5
Newbie
 
Join Date: Jan 2013
Posts: 3
Default

unusual damper problem


@techpappy can't do: upon further inspection, it looks like the ribbon is cut to size and both ends are "fattened" to jam into the black "roller" and the orange damper blade control, respectively. It's rubberized plastic so it can't be welded and it can't be glued because the break happened right at the roller (and it needs to be flexible + move frequently in 140+F heat). There is no more than 1mm of extra room inside the roller. The rest of the space is taken up by the motor drive shaft.

Quite a conundrum.
TobinB is offline   Reply With Quote
Old 01-03-2013, 04:46 PM   #6
Member
 
Join Date: Jul 2012
Location: Toronto ON
Posts: 599
Default

unusual damper problem


Sorry..Looked at your pic and have.been looking online for over 2 hours..no luck so far..maybe best to buy new but wait a little while to see if anyone can identify..also maybe remove unit to see if you can find mnfctrer's info.
techpappy is offline   Reply With Quote
Old 01-03-2013, 06:14 PM   #7
Member
 
Join Date: Oct 2011
Location: pa
Posts: 4,248
Default

unusual damper problem


sorry to say this....replace them all ..now or later....just replace them... will always be an issue....ben sr

ben's plumbing is offline   Reply With Quote
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
American Standard intermittent inducer problem with presssure switch warning no such user HVAC 5 12-26-2011 05:20 PM
75 year chimney leak problem mstanleyg Building & Construction 10 03-30-2010 12:38 PM
Installing Flue Liner thru Damper MikeinBurien Building & Construction 0 10-16-2009 11:39 PM
Stymied by window leakage problem. Matth3w General DIY Discussions 5 06-11-2008 06:26 PM
Post-Tension Slab Problem Advice/Help Mike McBride Building & Construction 2 01-09-2007 01:51 PM




Top of Page | View New Posts

Copyright © 2003-2014 Escalate Media. All Rights Reserved.