DIY Chatroom Home Improvement Forum

DIY Chatroom Home Improvement Forum (
-   HVAC (
-   -   two discharge lines on compressor? (

cmac 05-31-2008 08:34 AM

two discharge lines on compressor?
Hey guys,

Had a question on a replacement a/c compressor--it's a two and three quarter ton copeland reciprocating compressor. I'm confused on the discharge lines though--it's got a three quarter inch suction fitting near the top but also a smaller three eigths fitting next to it along with a three eigths discharge fitting near the bottom. I assume the three eigths fitting near the top is an additional discharge fitting?!?


8 Ball 05-31-2008 09:29 AM

The 3/8 fitting on the bottom is the discharge, the top 3/8 fitting is actualy a suction access. Braze a schreader type fitting on it or. just braze it closed.

cmac 05-31-2008 10:16 PM

thanks 8-ball, I appreciate it