Old 07-07-2010, 03:41 PM   #16
Member
 
Join Date: Nov 2008
Location: palm coast fl
Posts: 588
Share |
Default

Trane blower question


its probably too late but you can always convert that motor to a non variable speed motor just add a relay

kennzz05 is offline   Reply With Quote
Old 07-07-2010, 04:39 PM   #17
Newbie
 
Join Date: Jul 2010
Posts: 11
Default

Trane blower question


Quote:
Originally Posted by kennzz05 View Post
its probably too late but you can always convert that motor to a non variable speed motor just add a relay
Why too late? And how? That was an option, but I didn't have the knowledge to get it done. Thanks again.
HVAC dummy is offline   Reply With Quote
Old 07-08-2010, 04:48 PM   #18
Newbie
 
Join Date: Jul 2010
Posts: 11
Default

Trane blower question


Quote:
Originally Posted by kennzz05 View Post
its probably too late but you can always convert that motor to a non variable speed motor just add a relay

I'm interested! Please speak to me. Thanks
HVAC dummy is offline   Reply With Quote
Old 07-11-2010, 02:53 PM   #19
Newbie
 
Join Date: Jul 2010
Posts: 11
Default

Trane blower question


Quote:
Originally Posted by kennzz05 View Post
its probably too late but you can always convert that motor to a non variable speed motor just add a relay

Are you just a tease? Thanks
HVAC dummy is offline   Reply With Quote
Old 07-11-2010, 08:47 PM   #20
Member
 
Join Date: Oct 2009
Location: Nebraska
Posts: 2,362
Default

Trane blower question


Y and C to relay coil. EAC terminal hooked to the center post of the relay, normally closed post hooked to cooling speed and normally open post hooked to heating speed. Only works with a standard motor,not a V drive.

Last edited by Marty S.; 07-11-2010 at 08:49 PM.
Marty S. is offline   Reply With Quote
Old 07-11-2010, 08:51 PM   #21
An old Tradesmen
 
Join Date: Oct 2008
Location: PA
Posts: 25,052
Default

Trane blower question


Quote:
Originally Posted by Marty S. View Post
Y and C to relay coil. EAC terminal hooked to the center post of the relay, normally closed post hooked to cooling speed and normally open post hooked to heating speed. Only works with a standard motor,not a V drive.
So how you controlling the speed, in heating mode. Since its a 2 stage furnace.

Too high of a speed in first stage heat, and you can condensate in the primary heat exchanger. And rot it out.

Too low in second stage, and you over heat the heat exchanger.

beenthere is offline   Reply With Quote
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
Bryant Plus 90 - No Blower Ducaticorse HVAC 11 10-16-2012 08:39 PM
Comfortmaker blower intermittent problem jh44ny HVAC 12 07-31-2011 06:41 PM