standing pilot gas usage
This spring, I replaced my 20 year old Rheem furnace with a new 94+ efficient model.
Trying to compile gas savings from my old bills and wonder if any of the PROs could approximate (cu ft) how much a standing pilot would consume.
Thanks.
V
|
|
|
Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. DIYChatroom.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any home improvement task!
11-23-2008, 11:39 AM
|
#2
|
|
Member
Join Date: Oct 2008
Location: Suburbs of Detroit Mi
Posts: 3,702
|
standing pilot gas usage
To keep it simple during saving calculations the industry accepted rate was 10%.
Hope that helps.
BTW how is the new system working?
__________________
Just slow, not stupid.
|
|
|
11-23-2008, 05:26 PM
|
#3
|
|
Member
Join Date: Nov 2008
Posts: 263
|
standing pilot gas usage
Quote:
Originally Posted by hvaclover
To keep it simple during saving calculations the industry accepted rate was 10%.
Hope that helps.
BTW how is the new system working?
|
Would that be 10% of the input BTUs? The old beast was a 125,000 behemoth. Wow, 12,500. I can't imagine 10 times that little trickle equaling those 4 burners, but that large number will make my savings look better. Oh, well.
Got a Rheem Modulating furnace 90,000. A 75 probably would have covered me, but needed the 4 ton blower for a/c. Love that LOoooonnng gentle heat.
Thanks.
V
P.S., you needs to file down them teeth.
|
|
|
11-23-2008, 07:54 PM
|
#4
|
|
Member
Join Date: Nov 2008
Posts: 263
|
standing pilot gas usage
Quote:
Originally Posted by hvaclover
To keep it simple during saving calculations the industry accepted rate was 10%.
Hope that helps.
BTW how is the new system working?
|
Would that be 10% of the input BTUs? The old beast was a 125,000 behemoth. Wow, 12,500. I can't imagine 10 times that little trickle equaling those 4 burners, but that large number will make my savings look better. Oh, well.
Got a Rheem Modulating furnace 90,000. A 75 probably would have covered me, but needed the 4 ton blower for a/c. Love that LOoooonnng gentle heat.
Thanks.
V
P.S., you needs to file down them teeth.
|
|
|
11-23-2008, 10:55 PM
|
#5
|
|
Member
Join Date: Oct 2008
Location: Suburbs of Detroit Mi
Posts: 3,702
|
standing pilot gas usage
Those teeth are "Lady Killers". LOL
__________________
Just slow, not stupid.
|
|
|
11-24-2008, 06:12 AM
|
#6
|
|
Member
Join Date: Nov 2008
Posts: 263
|
standing pilot gas usage
Quote:
Originally Posted by hvaclover
Those teeth are "Lady Killers". LOL
|
O.K., I'll let the teeth slide, but when you say 10%, are you saying that doing away with the pilot saves 10%?
V
|
|
|
11-24-2008, 09:13 AM
|
#7
|
|
Member
Join Date: Oct 2008
Location: Suburbs of Detroit Mi
Posts: 3,702
|
standing pilot gas usage
Quote:
Originally Posted by veesubotee
O.K., I'll let the teeth slide, but when you say 10%, are you saying that doing away with the pilot saves 10%?
V
|
that was the hype when they went from standing pilot to spark.
All the furnaces that came off the assembly line were classified as 70% efficient,
__________________
Just slow, not stupid.
|
|
|
11-24-2008, 11:00 AM
|
#8
|
|
Member
Join Date: Nov 2008
Posts: 263
|
standing pilot gas usage
Quote:
Originally Posted by hvaclover
that was the hype when they went from standing pilot to spark.
All the furnaces that came off the assembly line were classified as 70% efficient,
|
Well, not being a nit picker (read, pain in the ass), I went exploring on the net. Came up with a very interesting link: http://www.osti.gov/energycitations/...sti_id=6471521 .
One paragraph read in part: "Overall, elimination of the pilots would have conserved only 2.6% of the total gas energy used in this home (3.1% if the home was air-conditioned)".
So what I intend to do is subtract about 2% to my calculated other use gas consumption for the non-heating months .
Last edited by veesubotee; 11-24-2008 at 01:02 PM.
|
|
|
11-24-2008, 03:17 PM
|
#9
|
|
Member
Join Date: Oct 2008
Location: Suburbs of Detroit Mi
Posts: 3,702
|
standing pilot gas usage
I see no need to justify my response to you. At the time the generation furnaces after standing pilot were all GAMA certfied to 70% according to US DOE standards. If you found something you like better than don't ask if you get a answer you don't like.
You would be wise to compare the Gama data to what you are now looking at. There are some allowances and dis allowances in design to consider.
__________________
Just slow, not stupid.
Last edited by hvaclover; 11-24-2008 at 03:20 PM.
|
|
|
11-24-2008, 05:00 PM
|
#10
|
|
An old Tradesmen
Join Date: Oct 2008
Location: PA
Posts: 18,642
|
standing pilot gas usage
Different units/brands, had different pilot set ups.
Some used more gas then others.
Also.
That study did not test for the effect of the increase in infiltration that a standing pilot has on a house.
The uncrease of infiltration increases a homes heat loss. But that was not considered, or allowed for in that study.
That study is flawed in reguards to saving on heating and cooling cost.
|
|
|
11-24-2008, 05:23 PM
|
#11
|
|
Member
Join Date: Nov 2008
Posts: 263
|
standing pilot gas usage
Quote:
Originally Posted by hvaclover
I see no need to justify my response to you. At the time the generation furnaces after standing pilot were all GAMA certfied to 70% according to US DOE standards. If you found something you like better than don't ask if you get a answer you don't like.
You would be wise to compare the Gama data to what you are now looking at. There are some allowances and dis allowances in design to consider.
|
Hey Lover, don't be mad. I'm was just trying to understand what you are saying. I misunderstood your original statement (70%) as referring to furnaces of 80% AFUE (80 - 10 = 70). Probably still do.
I looked at GAMA and it's way over my head.
My old beast was built in 1987. Don't know if 80s were around then.
What I was trying to do, was compare my old gas usage on a therms per heating degree day basis. I know that HDDs are based on average temperatures without any weighting, but over the period of a year, the errors should be a wash.
To try to get as accurate figures as possible, I used my gas consumption during the non-heating months as my baseline (cooking and hot water) use. I didn't make any allowance for the pilot which has been on year 'round. That was the basis for my original question.
So, thanks and sorry to have ruffled your feathers. I'll let you bite me in the neck.
V
|
|
|
11-24-2008, 06:56 PM
|
#12
|
|
Member
Join Date: Oct 2008
Location: Suburbs of Detroit Mi
Posts: 3,702
|
standing pilot gas usage
Quote:
Originally Posted by beenthere
Different units/brands, had different pilot set ups.
Some used more gas then others.
Also.
That study did not test for the effect of the increase in infiltration that a standing pilot has on a house.
The uncrease of infiltration increases a homes heat loss. But that was not considered, or allowed for in that study.
That study is flawed in reguards to saving on heating and cooling cost.
|
Hey Been, how's the family?
Are you Talking about the efficiency standards Gama used to first assign the 70% rating and the later arguments that later disallowed jacket heat losses or the study the OP mentioned?
__________________
Just slow, not stupid.
|
|
|
11-24-2008, 07:00 PM
|
#13
|
|
An old Tradesmen
Join Date: Oct 2008
Location: PA
Posts: 18,642
|
standing pilot gas usage
The study the OP posted.
Families doing good. Thanks.
How bout yours.
|
|
|
11-24-2008, 07:04 PM
|
#14
|
|
Member
Join Date: Oct 2008
Location: Suburbs of Detroit Mi
Posts: 3,702
|
standing pilot gas usage
Quote:
Originally Posted by beenthere
The study the OP posted.
Families doing good. Thanks.
How bout yours.
|
My wife is sweating bullets over the so called "Big Three Bail Out".
She works at Chrysler and is worried sick if she is going to have a job tomorrow.
otherwise everything is peachy.lol
__________________
Just slow, not stupid.
|
|
|
11-24-2008, 07:38 PM
|
#15
|
|
Newbie
Join Date: Nov 2008
Location: Chicago IL
Posts: 5
|
standing pilot gas usage
I have info on gas fireplaces, which should be relatively close to an older furnace...the gas valves in most current gas fireplaces use around 30,000 BTU's a day = about 110 therms a year. A NG therm costs constantly change but can routinely cost anywhere from 1.00 to 1.50. End result is about $100 to $150 a year. We(fireplace supplier) usually quote $10 to $12 to operate a NG pilot.
New fireplaces have an option for electronic ignition, which eliminates the need for an standing pilot...and then a $10 a month savings. Homeowners have to determine if they want to invest in the extra cost to have the electronic ignition option vs. the cost of operating a standing pilot.
|
|
|
-->
| Thread Tools |
Search this Thread |
|
|
|
| Display Modes |
Linear Mode
|
Posting Rules
|
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts
HTML code is Off
|
|
|
|
|