Hi,
I just replaced my blower motor it was a hd46ae120 GE ecm motor with the same motor but the only difference I see is the old control module said 2.0 and the new says 2.3 but the motor is the same. Why won't it shut off? Any advice would be appreciated. THANKS

robr1 is offline   Reply With Quote
Old 12-19-2008, 12:11 PM   #2
An old Tradesmen
 
Join Date: Oct 2008
Location: PA
Posts: 25,527
Rewards Points: 2,734
Default

Replaced blower motor in 58MVP now it wont shut off


Because its the wrong motor and module.

The 2.0 you had, is not controled by pulse width modulation, like the 2.3 you have wants.

beenthere is offline   Reply With Quote
Old 12-19-2008, 01:30 PM   #3
Newbie
 
Join Date: Dec 2008
Posts: 3
Rewards Points: 10
Default

Replaced blower motor in 58MVP now it wont shut off


Hi,
Thanks for the info, does the mvp's circuit board have anything to do with it? Would a new circuit board be able to use the pulse system?
Thanks
robr1 is offline   Reply With Quote
Old 12-19-2008, 04:08 PM   #4
An old Tradesmen
 
Join Date: Oct 2008
Location: PA
Posts: 25,527
Rewards Points: 2,734
Default

Replaced blower motor in 58MVP now it wont shut off


A new board designed to control pulse width, yes.

But, you'd be better off, taking that motor back, and getting the correct one.
beenthere is offline   Reply With Quote
Old 12-19-2008, 06:21 PM   #5
Newbie
 
Join Date: Dec 2008
Posts: 3
Rewards Points: 10
Default

Replaced blower motor in 58MVP now it wont shut off


Thank You!
robr1 is offline   Reply With Quote
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
Carrier 58MVP Blower Problem mickd HVAC 47 08-16-2014 04:52 PM
Blower will not shut off. lj4 HVAC 14 12-11-2011 02:16 AM
Newmac furnace blower won't shut off dsgreer HVAC 2 11-03-2008 01:23 PM
replaced furnace blower now breaker issue Kurr HVAC 5 01-25-2007 09:22 PM




Top of Page | View New Posts

Copyright © 2003-2014 Escalate Media. All Rights Reserved.