DIY Chatroom Home Improvement Forum

DIY Chatroom Home Improvement Forum (http://www.diychatroom.com/)
-   HVAC (http://www.diychatroom.com/f17/)
-   -   Looking for correct dual run capacitor value (http://www.diychatroom.com/f17/looking-correct-dual-run-capacitor-value-186838/)

swissmade 09-11-2013 12:29 PM

Looking for correct dual run capacitor value
 
1 Attachment(s)
Hello All,
My outside condenser unit stoped working last night.
I found it humming.
The dual run capacitor can is bulging.
The capacitor can is rusted and I can not find the MFD values anywhere.
I believe the condenser unit is a Concord.
Model: CCU10A30A-1
Any help is much welcome

yuri 09-11-2013 01:50 PM

1) try americanhvacparts.com and give them the unit model and serial or Graingers and they may be able 2 look it up 4 U

2) carefully rub some cooking oil or spray Pam on it and use a magnifying glass and it may lift them back up 4 U.

firedawgsatx 09-11-2013 01:53 PM

Are you able to find the installation/technical documentation that is supposed to be left on the unit when it is installed? It is usually found in an envelope taped somewhere near the electronics area on the condenser. If you locate it you should be able to find what the original run capacitor specs are. Another possibility is to look at the condenser fan motor. The label will show what size capacitor it requires (probably 5mfd). Then get the compressor part number and post it so we can look it up to see what size run capacitor it requires. When I can't read part numbers/info I like to take a digital photo of the part and then use the computer to enlarge the photo to really magnify the numbers/letters.

swissmade 09-11-2013 02:37 PM

2 Attachment(s)
Here is a photo of the compressor and capacitor

yuri 09-11-2013 02:50 PM

that is BAD. U will have to phone those suppliers. I have heard that Graingers can look it up and the other guys must B able 2.

firedawgsatx 09-11-2013 03:08 PM

Your compressor requires a 35mfd 370V run capacitor. Were you able to find the label on your condenser fan motor? That will tell you what size run capacitor required for that. I found reference to an air conditioner with model number SCU10A30A-1 (notice only first letter changed) that shows it takes a 35/5 MFD 370V dual run capacitor. These units are made by one company and then marketed under different names.

swissmade 09-11-2013 05:14 PM

Thanks to all
I obtained a 35/5 MFD 370VAC capacitor from Grainger.
Momma is now cool and happy.

yuri 09-11-2013 05:19 PM

Yur welcome:)

redman88 09-11-2013 05:19 PM

wish i had been able to pop down to a local store for a capacitor when mine when out. hand to order it off of amazon.

yuri 09-11-2013 05:22 PM

1 Attachment(s)
well at least you Yanks have quick delivery and lots of online sites to choose from (duty and customs/hassle free). where I am everything comes by dogsled.:laughing:

redman88 09-11-2013 05:37 PM

Quote:

Originally Posted by yuri (Post 1240788)
well at least you Yanks have quick delivery and lots of online sites to choose from (duty and customs/hassle free). where I am everything comes by dogsled.:laughing:

well move south to a better life :thumbup:

yuri 09-11-2013 06:03 PM

I hate snakes and allygators and hurrycanes.

Blizzards, I just stay inside the igloo until they blow over.:yes: