asstratford 10-10-2006 08:58 PM

Furnace won't lite-Coleman Model 900759-Help
 
Hello to everyone - here is my first question...
I cannot get the furnace to lite. Does anyone have information on this furnace ? It is fed by Propane. Do I have to lite the pilot myself?????
Thank you for any information you may have.:jester:
AS

redline 10-11-2006 08:19 AM

Does this unit have a standing pilot or electronic ignition?

asstratford 10-12-2006 11:55 AM

It is so old, I'm sure it's a standing pilot.

redline 10-12-2006 11:58 AM

can you see if the pilot light is even lit?

#CARRIERMAN 10-18-2006 05:24 PM

Hi Asstratford

This particular furnace should be electronic ignition. Locate the gas valve. There should be two white wires and a gray wire going inside the furnace just below the gas valve. If that is so, you probably just need a new hot surface ignitor. The part # is 1474-052p


Good luck, let me know if you need any more help.