DIY Chatroom Home Improvement Forum

DIY Chatroom Home Improvement Forum (http://www.diychatroom.com/)
-   HVAC (http://www.diychatroom.com/f17/)
-   -   Furnace lights for only 3 sec (http://www.diychatroom.com/f17/furnace-lights-only-3-sec-5581/)

robzimich 12-28-2006 10:56 AM

Furnace lights for only 3 sec
 
When it is time to heat the fan on the furnace comes on and the furnace lights for 2 or 3 seconds then goes out. About a minute later it will light again for 2 or 3 seconds then go out. This will happen for about 7 or 8 minutes until finally the furnace will stay lit. The fan will then come on and heat the house. The small blower? fan will stay running the whole time that it is trying to light but the big fan will only come on when it is up to temp. What is wrong with my furnace????

acefurnacefixer 12-28-2006 11:11 AM

Try cleaning the flame sensor.....its a steel rod oppiste the ignitor. Just remove it and hit it with some emry cloth or 200 grit sand paper.

Let us know how it turns out.