westomaha 12-25-2008 11:41 AM

Bryant Plus 80 Code 33 fan runs all time! ideas?
 
I have a Bryant Plus 80model 395cav048135 that runs for about 10 minutes (blows heat etc) then flames shut off but fan runs continuslythis when flashes code 33 till reignites and heats again. (aprox 10-15 minutes) have tried researching this am but no definte answers any ideas?http://www.askmehelpdesk.com/images/smilies/smile.gif

yuri 12-25-2008 12:09 PM

Code 33 means the unit is cutting out on the high temp limit control due to a lack of airflow. Make sure your air filter is clean/all vents clean and open/underside of your A/C coil not clogged with dirt.