Blower motor in old bryant furnace runs constantly


the other day i went into an apartment to do a "turn over" and noticed the furnace service switch was off. i turned it on and the blower kicked on immediately. so i went over to the thermostat and it was in the off position. fan in the auto position. then after noticing the blower running i noticed the condenser is turning on as well. i changed the thermostat and that wasnt the problem. so i thought ok it might be the board. changed the board the next day. same thing happens. when i disconnect the high speed wire for the blower from the board the blower motor hums and the condenser still comes on. the furnace is a 1988 bryant 70 %. any ideas? besides throwing it off a tall building.

GetYourShineBox is offline   Reply With Quote
Join DIYChatroom.com

Join the #1 DIY Forum Today - It's Totally Free!

DIYChatroom.com - Are you about to start a new home improvement task and need some help? Do you need advise on what products to buy? Or maybe you can give others some advice? No matter where you fit in you'll find that DIY Chatroom is a great community to join. Best of all it's totally free.

Join DIYChatroom.com - Click Here
JOIN FOR FREE


Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. DIYChatroom.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any home improvement task!
Old 07-15-2010, 11:28 PM   #2
An old Tradesmen
 
Join Date: Oct 2008
Location: PA
Posts: 18,646
Default

Blower motor in old bryant furnace runs constantly


Get your meter out, and check for shorts in the low voltage wiring.

beenthere is online now   Reply With Quote
Old 07-20-2010, 08:49 PM   #3
Member
 
GetYourShineBox's Avatar
 
Join Date: Sep 2009
Location: Waterford, MI
Posts: 69
Default

Blower motor in old bryant furnace runs constantly


refresh
GetYourShineBox is offline   Reply With Quote
Reply


-->
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
Bryant Furnace main burner goes out after 5 seconds Da_Bears HVAC 8 01-03-2012 02:24 AM
Blower fan runs constantly epowerfan HVAC 65 12-06-2011 07:57 AM
Problems with new furnace..Overheating, having to reset. Furnace too big? Tommy2 HVAC 41 12-01-2008 02:55 PM
furnace blower constantly running HELP! ice_wolf69 HVAC 16 10-26-2008 07:11 PM
Furnace Blower Problem SGecko HVAC 2 09-27-2006 11:16 AM


Top of Page | View New Posts


All times are GMT -4. The time now is 08:42 PM.


© 2003 - 2010 The Building Network LLC